7. TECHNICAL SPECIFICATIONS
7.1. TECHNICAL CHARACTERISTICS
Accuracy is calculated as ±[%reading + (dgt x resolution)] to 18°C28°C,
<75%RH
DC Voltage
Range
Resolution
400.0mV
0.1mV
4.000V
0.001V
40.00V
0.01V
400.0V
0.1V
600V
1V
Overload protection: 600V DC/ACrms
AC TRMS Voltage
Range
Resolution
4.000V
0.001V
40.00V
0.01V
400.0V
0.1V
600V
1V
(*) Accuracy specified from 5% to 100% of the measuring range
Frequency range: 50Hz60Hz (not sinusoidal waveform), 45Hz 1kHz (sinusoidal waveform)
Overload protection: 600V DC/ACrms
Crest factor: 3 (up to 300V), 1.5 (up to 600V),
Resistance and Continuity test
Range
Resolution
400.0
4.000k
0.001k
40.00k
0.01k
400.0k
0.1k
4.000M
0.001M
40.00M
0.01M
Overload protection: 600V DC/ACrms
DC Current
Range
Resolution
400.0A
0.1A
4000A
1A
40.00mA
0.01mA
400.0mA
0.1mA
4.000A
0.001A
10.00A
0.01A
AC TRMS Current
Range
Resolution
400.0A
0.1A
4000A
1A
40.00mA
0.01mA
400.0mA
0.1mA
4.000A
0.001A
10.00A
0.01°
(*) Accuracy specified from 5% to 100% of the measuring range
39
Accuracy
(1.0rdg + 3dgt)
Accuracy (*)
(50Hz ÷ 60Hz)
(1.0%rdg+3dgt)
Accuracy
0.1
(1.5%rdg+5dgt)
(2.5%rdg+20dgt)
Accuracy
(1.0%rdg+3dgt)
(1.2%rdg+3dgt)
Accuracy (*)
(50Hz ÷ 60Hz)
(1.2%rdg +3dgt)
(1.8%rdg+5dgt)
IRONMETER
Input impedance
>10M
Input impedance
>10M
Buzzer
≤50
Overload protection
Fast fuse
500mA/600V
Fast fuse 10A/600V
Overload protection
Fast fuse
500mA/600V
Fast fuse 10A/600V