Parameter
Permissible operating pressure
Connection
Nominal diameter
Electrical data
Degree of protection (as per EN
60529)
4.3.3
Capsule pressure gauge
Parameter
General specifications
Ranges (EN 837-3/5)
Accuracy (as per EN 837-3)
Nominal size 63, nominal
size 100, nominal size 160
Temperature performance
Application ranges
Static load
Dynamic load
Overpressure safety
Product description
Value
Maximum ¾ x full scale value
Clamp as per ISO 2852
DN1
and DN2
1
/
2
> 25 bar = IP 65
< 25 bar = IP 54
Value
0/25 to 0/1,000 mbar and all corre-
sponding vacuum and compound
ranges with overpressure protection
Cl. 1.6
+/- 0.6 % / 10 K
(indication error when the temperature
of the measuring system deviates from
the normal temperature of 20 °C, with
reference to the full scale value)
Full scale value
0.9 x full scale value
Full scale value
RF ... EX / KP ... EX
EN
13