LIVRE_ECT7000P.book Page 6 Jeudi, 1. mars 2012 3:55 15
1. Remove the oil filler cap [1] and the oil drain screw [2].
2. Reinstall the oil drain screw [2] fitted with its seal [3] and tighten
securely.
3. Pour in oil of the recommended type
the level reaches the top of the filler neck.
[1]
Oil capacity: 1,1
NOTE: Protection of the environment: Waste oil is a serious
source of pollution of our environment; we strongly recommend that
you take it in a leak-proof container to a service station or a waste
disposal site, which will recycle it. Do not throw oil away with
household waste, and do not dispose of it by pouring it away on the
ground or down the drain.

AIR CLEANER MAINTENANCE

The engine will not run properly if the air cleaner is dirty: it is very
important that the air cleaner is serviced regularly.
Never use petrol or inflammable solvents to clean air cleaner
elements: these products can cause fire and damage the air
cleaner elements.
1. Remove wing nut [4] and the air filter
cover [5]. Remove wing nut [8] and
elements [6] and [7], and separate
them. Carefully check for cracks on the
two elements and make sure they are
not clogged. Replace the elements if
they show signs of damage.
2. Paper element [6]: Tap the element
lightly several times on a hard surface
to remove impurities or clean the
element by blowing compressed air
from the inside towards the outside. Do
not brush the element as this would
cause the impurities to become
embedded in the fibres. Replace the
paper element if it is very dirty.
3. Foam element [7]: Wash the element in
a solution of warm water and non-
foaming household detergent, then
rinse and allow it to dry completely or,
alternatively, wash it in a nonflammable solvent and allow it to
dry completely. Soak the element in clean oil and squeeze out
the excess oil. If too much oil is left in the foam filter, the engine
will smoke the next few times it is started up.
4. Reinstall air filter elements [6] and [7], the wing nut [8] and the
cover [5]. Tighten the wing nut correctly [4].
CAUTION:
• Do not use the generator without its air cleaner, as this can
damage the engine.

CHECKING THE SPARK PLUG

Recommended spark plugs:
BPR6ES (NGK), W20EPR-U (NIPPONDENSO Co. Ltd)
CAUTION:
• Only use the recommended type of spark plug.
• The use of spark plugs with an incorrect heat range can cause
damage to the engine.
6 EN
If the engine has been running, do not touch the muffler or the
spark plug as you risk burning yourself.
(see page
3) and check that
1. Remove the spark plug cap and unscrew the spark plug with a
2. Inspect the spark plug closely and replace it if there are heavy
3. Measure the plug gap with a set of feeler
[3]
[2]
4. Check that the spark plug washer is in good
CAUTION:
• Never clean the spark plug by sand blasting.
5. When installing a new spark plug, tighten by 1/2 turn with a
CAUTION:
• The spark plug must be properly tightened or else it is likely to
CLEANING THE SEDIMENT
CUP
Shut off the fuel valve. Remove the
sediment cup [9] and O-ring [10] and
clean them in a nonflammable solvent.
[4]
Allow the parts to dry completely and
then reinstall them. Turn the fuel valve
ON and check for leaks.
[5]

MAINTENANCE SCHEDULE

[8]
To ensure that the generator performs correctly and has a long
working life, it is essential that the maintenance schedule be
[6]
observed.
Perform this maintenance at every
indicated month or operating hour
[7]
interval, whichever comes first.
Item
Engine oil
Air filter
Sediment cup
Spark plug
Combustion
chamber and
valves
Valve clearance
Fuel tank
and filter
Fuel line
Spark arrester
(1) Clean more often if used in a dusty environment.
(2) Maintenance of these points must be carried out by a Honda dealer.
(3) In Europe and other countries where the machinery directive 2006/42/EC is
spark plug wrench.
deposits on the electrodes or if the insulator is cracked or
damaged. Clean the spark plug with a wire brush.
gauges. The gap should be between 0.7 and 0.8
mm. If it has to be corrected, carefully bend the
side electrode.
condition, then screw the spark plug in as far as
it will go by hand.
spark plug wrench to compress the washer. When reinstalling a
used spark plug, tighten by 1/8 or 1/4 turn with a plug wrench.
Reinstall the spark plug cap.
overheat considerably, causing damage to the engine.
On
each
use
Intervention
Check oil
level
Replace
Replace
Check
Clean
Clean
Clean / Adjust
Clean
Check / Adjust
Clean
Check.
Every 2 years (replace if necessary) (2)
Check
Clean
enforced, this cleaning should be done by your servicing dealer
0.7 ~ 0.8 mm
[10]
[9]
Frequency
1st
After
Every
Every
month
3
6
year
or
months
months
or
after
or 50
or 100
300
20
hours
hours
hours
hours
[3]
[3]
(1)
[3]
After every 500 hours (2)
(2)
(2)
(3)
(3)
.

Werbung