8.4.3 Smart Mode
Currently, only Smart Mode is provided. Smart Mode can automatically select the best operating strategy
based on the device configuration within the system and electricity prices.
• Smart Mode Operation Strategy:
-If a Smart Meter is configured, the output of the energy storage device is dynamically controlled according to
the real-time monitoring data of the Smart Meter.
-If there is no Smart Meter but a smart appliance is configured, the output of the energy storage device is
dynamically controlled according to the real-time monitoring data of the smart plug.
-If there is neither a Smart Meter nor a smart plug, the output of the energy storage device is controlled
according to the basic load plan.
-Smart Meter > Smart Plug > Basic Load Plan
-Under dynamic electricity prices, discharge according to the strategy during high and normal electricity price
periods, and charge during low electricity price periods.
If you need to quickly switch the system to a certain strategy, you just need to directly add or remove devices
in the system settings, adjust the electricity price settings, and adjust the basic load curve.