Product running time
The total running time for the product is shown on the
display.
Important working instructions
• The compressor on the product switches on with a
delay of around 3 minutes after switching the prod-
uct on.
• The temperature range in which the product can
work properly is from approx. +5°C to approx.
+35°C.
• During the defrosting phase, the compressor is
switched off and the fan continues to run normally.
• We recommend cleaning the filter material around
once per month. To do this, wash it out carefully
with clean, warm water.
• We recommend maintaining a safety distance be-
tween the wall and the air inlet/outlets.
• Please empty the collection bucket each time after
using the product.
• If you do not wish to use the product for an extend-
ed period, disconnect the product from the power
supply and attach the power cable to the product.
• Please do not tilt the product by more than 45°, nei-
ther during transport nor during use.
• If the product has been tilted inadvertently, wait at
least 12 hours before using the product.
10. Maintenance
The product is designed for problem-free operation
and minimal monitoring.
All moving parts are permanently lubricated.
The product has no further internal parts that require
maintenance.
Cleaning
• Keep protective devices, air vents and the motor
housing as free of dust and dirt as possible. Rub
the product clean with a clean cloth or blow it off
with compressed air at low pressure.
• We recommend that you clean the product directly
after every use.
• Clean the product at regular intervals using a damp
cloth and a little soft soap. Do not use any cleaning
agents or solvents; they could corrode the plastic
parts on the product. Ensure that no water can pen-
etrate the interior of the product.
Service information
With this product, it is necessary to note that the fol-
lowing parts are subject to natural or usage-related
wear, or that the following parts are required as con-
sumables.
Wearing parts*: Wheels
* may not be included in the scope of delivery!
Spare parts and accessories can be obtained from
our Service Centre. To do this, scan the QR code on
the front page.
11. Electrical connection
The customer's mains connection as well as the
extension cable used must also comply with the-
se regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is of-
ten damaged.
This may have the following causes:
Pressure points, where connection cables are pas-
•
sed through windows or doors.
Kinks where the connection cable has been impro-
•
perly fastened or routed.
•
Places where the connection cables have been cut
due to being driven over.
Insulation damage due to being ripped out of the
•
wall outlet.
Cracks due to the insulation ageing.
•
Such damaged electrical connection cables must not
be used and are life-threatening due to the insula-
tion damage.
Check the electrical connection cables for dama-
ge regularly. Ensure that the connection cables are
disconnected from electrical power when checking
for damage.
Electrical connection cables must comply with the
applicable VDE and DIN provisions. Only use con-
nection cables with the designation H05RR-F.
The printing of the type designation on the connec-
tion cable is mandatory.
The mains voltage must be 230 V~
•
•
Extension cables up to 25 m long must have a
cross-section of 2.5 mm².
Connection type Y
If it is necessary to replace the mains connection ca-
ble, this must be done by the manufacturer or their
representative to avoid safety hazards.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.
Please provide the following information in the event
of any enquiries:
•
Machine data - type plate
www.scheppach.com