Continuous tone
The horn sounds (continuous tone) when the cooling air
filter is clogged.
1. Allow the device to cool down. Clean/replace the
cooling air filter.
Anti-static system
Static charges are discharged through the earthed con-
nection nozzles. This prevents sparking and electric
shocks with electrically conducting accessories (includ-
ed in the scope of delivery).
Dry vacuuming
● NT 30/1: For particularly dust-free dirt disposal
when vacuuming small to medium quantities of fine
dust, we recommend using a fleece filter bag with
cap, order number 2.889-154.0 (5 pieces). The de-
vice is fitted with a fleece filter bag.
● NT 40/1, NT 50/1: For particularly dust-free dirt dis-
posal when vacuuming small to medium quantities
of fine dust, we recommend using a fleece filter bag
with cap, order number 2.889-155.0 (5 pieces). The
device is fitted with a fleece filter bag.
● For vacuuming large quantities of fine dust, we rec-
ommend using a dust bag with cable tie, order num-
ber 2.889-231.0 (10 pieces). The device is fitted with
a dust bag.
Note
All types of dust up to dust class M can be vacuumed
with this device. The use of a dust collection bag (for or-
der no. see filter systems) is required by law.
Note
The device is suitable for industrial extraction and as a
dust remover for mobile operation for vacuuming dry,
flammable dusts with workplace limit values (AGW)
greater than or equal to 0.1 mg/m
Installing the fleece filter bag
1. Unlock and remove the suction head.
2. Fit the fleece filter bag.
Illustration C
3. Fit and lock the suction head.
Installing the dust bag
1. Unlock and remove the suction head.
2. Insert the dust bag.
Illustration D
3. Pull the dust bag over the container. Ensure that the
marking line is within the container and the ventila-
tion hole is positioned on the back wall of the con-
tainer.
4. Fit and lock the suction head.
Wet vacuum cleaning
DANGER
Danger from dust that is harmful to your health
Respiratory sicknesses through inhalation of dust.
No dusts harmful to health may be vacuumed when per-
forming wet vacuum cleaning.
Note
The candle filter available as an accessory with the or-
der number 2.414-000.0 is not suitable for wet vacuum
cleaning.
Installing the squeegees
1. Remove the brush strip.
Illustration E
2. Install the squeegees.
16
3
.
English
Closing the suction connection
1. Fit a plug exactly into the suction connection.
Illustration F
2. Push the plugs in until they engage.
Removing the fleece filter bag
● The fleece filter bag must always be removed when
vacuuming wet substances.
1. Unlock and remove the suction head.
2. Pull the fleece filter bag on the flange up and out.
Illustration G
3. Seal the fleece filter bag with cap.
4. Dispose of the used fleece filter bag in accordance
with statutory regulations.
5. Fit and lock the suction head.
Removing the dust bag
● The dust bag must always be removed when vacu-
uming wet substances.
1. Unlock and remove the suction head.
2. Fold up the dust bag.
Illustration H
3. Take off the protective film and close the ventilation
hole with a self-adhesive tab.
4. Seal the dust bag tightly underneath the opening us-
ing cable ties.
5. Remove the dust bag.
6. Clean the container inside with a moist cloth.
7. Dispose of the dust bag in accordance with statutory
regulations.
8. Fit and lock the suction head.
Draining the waste water
NT 50/1 only:
1. Drain the waste water via the drain hose.
Illustration I
General
● We recommend switching off the "Automatic filter
dedusting" function when vacuuming wet dirt with
the crevice nozzle or the upholstery nozzle (option-
al), or when sucking mainly water out of a container.
● The device switches off automatically when the
maximum fluid level is reached.
● When vacuuming non-conductive liquids (e.g. drill
emulsion, oils and grease) the device does not au-
tomatically switch off when the container is full. The
filling level must be continuously monitored and the
container emptied on a timely basis.
● On completion of wet vacuum cleaning: Clean the
main filter element using the dedusting function and
let it dry. Clean the electrodes with a brush. Clean
the container with a moist cloth and dry it off.
Clip connection
The suction hose is equipped with a clip system. All ac-
cessory parts with a nominal width of 35 mm can be
connected.
Illustration J
Operation
Note
The suction hose must be handled carefully during op-
eration to avoid kinks.
Each time before use
1. Check all filters for correct position and damage.