Appendix

A

Pressure loss curve

B
140
120
100
80
60
40
20
0
0
3
A
Volume flow: [m
B

Technical data

Technical data
Nominal capacity
Outer diameter of the cylinder
Height of the cylinder
Net weight
Weight when filled with water
Material of the cylinder and the connections
Water pressure range
Maximum operating temperature
Diameter of the water connections
Diameter of the sensor pocket
Maximum volume flow
24
1
2
/h]
3
4
5
Pressure loss Δp: [mbar]
B
VPS R 100/1 M
101 l
550 mm
932 mm
34 kg
135 kg
Steel
0.1 ... 0.3 MPa
(1.0 ... 3.0 bar)
95 ℃
G1" 1/2
G1/2
6 m³/h
Operating and installation instructions 0020244064_02
6
A
VPS R 200/1 B
202 l
600 mm
1,202 mm
44 kg
246 kg
Steel
0.1 ... 0.3 MPa
(1.0 ... 3.0 bar)
95 ℃
G1" 1/2
G1/2
6 m³/h
Inhaltsverzeichnis