4.6
Observing the requirements for the
product's installation site
Ensure that the room in which the product is installed is
not heated to the maximum recommended room temper-
ature.
Recommended room temperature: 20 ℃
Do not install the product above another unit that may
damage it (e.g. above a cooker that produces steam and
grease) or in a room with a high level of exposure to dust
or in a corrosive environment.
Do not install the product below a unit from which liquids
may flow.
Ensure that the room in which you want to set up the
product is sufficiently protected against frost.
4.7

Wall-mounting the product

Validity: VPS R 100/1 M
Caution.
Risk of injury caused by the product tip-
ping.
If the product is not properly secured to the
wall, you cannot rule out that the product will
tip.
Use the four fixing points to secure the
product to the wall.
Check how tight the nuts are. After tight-
ening them, the threaded pins must pro-
trude out of the nuts.
1.
Ensure that the wall offers sufficient load-bearing
capacity to bear the weight of the product when it has
been filled.
Weight when filled with water: 135 kg
2.
Check whether the supplied fixing accessories are
suitable for the wall type.
3.
Remove the fixing screws from the cylinder below the
pallet.
4.
Secure the lower cover below the cylinder.
0020244064_02 Operating and installation instructions
1
2
3
Condition: The load-bearing capacity of the wall is sufficient; the fixing
material is permitted for the wall
A
B
Attach the wall-fixing strips to the cylinder.
Secure the cylinder to the wall.
Condition: The load-bearing capacity of the wall is not sufficient
Ensure that wall-mounting apparatus on-site has a suf-
ficient load-bearing capacity. Use individual stands or
primary walling, for example.
4.8

Installing the product

1.
When selecting the installation site, note the weight of
the filled cylinder and the load-bearing capacity of the
floor.
Weight when filled with water
Validity: VPS R 100/1 M
Validity: VPS R 200/1 B
2.
Remove the cylinder's fixing screw from the bottom of
the pallet.
C
D
135 kg
246 kg
1
2
4
3
19