Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Standard Installation - Bwt Rtm Cs S-500 Bedienungsanleitung

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

1.

INSTALLATION INSTRUCTIONS

Installation of the filter assembly below the water level of the pool is highly recommended. In the event that
the filter is installed above the pool water level, a check valve, accessible through a service hatch, must
be installed on the suction line.
Allow a surface area of 1200 mm x 1200 mm for the installation.
Position the control panel as close as possible to the multiport valve to facilitate manipulations.
To prevent vibrations, and any resonance effect, insert a sheet of soft rubber between the base of the
pump and the ground.
1.1

Standard installation

A - B :
Skimmer
C :
Main drain
D :
Vacuum point
E :
Return fitting
F :
Drain
16/48
2021/01 - Indice de révision : I - Code : 26690
VALVE
FILTER
(OPTION)
Ø 500
1''1/2
Ø 610 A
1''1/2
Ø 610 B
2''
Ø 760
2''
Ø 920
2''
D
A B C
A
B
C
802
503
800
417
840
612
915
418
840
612
930
418
985
762
1083
495
1111
923
1245
557
F
E
CONSTRUCTION & RÉNOVATION
D
E
476
477
493
576
638
Inhaltsverzeichnis