Verification ok / Überprüfung in Ordnung:
Obligations for charge point operator (CPO) and emobility service providers (EMSP)
/ Verpflichtungen für Ladepunktbetreiber (CPO) und Anbieter von E-Mobilitätsdiensten (EMSP).
Measurement Accuracy Notes According to the Type Examination Certificate
I.
Obligations for the Operator of the Charging Station, which must be fulfilled as a necessary prerequisite for
the proper operation of the charging station.
The operator of the charging station is considered the user of the measuring device within the meaning of § 31
of the Measurement and Calibration Act (Mess- und Eichgesetz).
A.
The charging station is only considered to be used in accordance with the calibration law if it is not exposed to
environmental conditions other than those for which its type examination certificate was issued. These conditions
are described in the technical documentation accompanying the charging station.
B.
The user of this product must include the PK (Public Key) indicated at the charging station for the charging points
when registering the charging points with the Federal Network Agency. Without this registration, operation of the
charging station in compliance with calibration law is not possible. Weblink:
www.bundesnetzagentur.de/DE/Fachthemen/ElektrizitaetundGas/E-Mobilitaet/Ladesaeulenkarte/Karte/start.html
C.
The user of this product must ensure that the calibration validity period for the charging station itself is not
exceeded. The user must store the data packets signed and read from the charging station, corresponding to the
pagination, permanently (also) on hardware dedicated to this purpose in his possession ("dedicated storage").
These data must be made available to authorized third parties (obligation to operate the storage). Furthermore,
the user must permanently retain metering and additional modules removed from the charging station and enable
the reading of the stored calibration logbooks when required by an authorized authority. "Permanently" means
that the data must be stored not only until the conclusion of the business transaction but at least until the expi-
ration of possible statutory appeal periods for the business transaction. Substitute values may not be formed for
billing purposes for data that is not available.
D.
The user of this product must provide measuring value users who receive and use measured values from this
product in business transactions with an electronic version of the operating instructions approved by the
conformity assessment body. In doing so, the user of this product must particularly draw attention to section II
"Obligations for the User of the Measured Values from the Charging Station".
E.
The user of this product is subject to the notification requirement according to § 32 MessEG (excerpt): § 32
Notification Requirement (1) Anyone who uses new or renewed measuring devices must notify the authority
responsible under state law no later than six weeks after commissioning.
If required by authorized authorities, the user of the measuring device must provide the complete content of the
dedicated local storage or the storage at the CPO with all data packets for the billing period.
II.
Obligations for the User of the Measured Values from the Charging Station (EMSP)
The user of the measured values must comply with § 33 of the MessEG:
§ 33 MessEG (quote)
§ 33 Requirements for the Use of Measured Values
A.
Values for measured quantities may only be specified or used in commercial or official transactions or in measure-
ments in the public interest if a measuring device was used properly for their determination and the values can be
traced back to the respective measurement result, unless otherwise specified in the legal ordinance pursuant to §
41 number 2. Other federal legal regulations serving comparable protective purposes continue to apply.
B.
Anyone who uses measured values must, within their capabilities, ensure that the measuring device meets legal
requirements and must obtain confirmation from the person using the measuring device that they have fulfilled
their obligations.
32
Verification failed / Überprüfung fehlgeschlagen: