CAUTION
When tensioning, the strap can tear and whip away. Do not stand in the alignment of the
strap. Wear eye protection.
► Press the tensioning button (6) with the
thumb of your right hand.
The tool pulls it over the seal and the
strap is tensioned until the desired strap
tension is reached. When the tensioning
force is reached, a short green light on the
control panel will indicate this.
In addition, the set tensioning force and
the status indicator bar with the achieved
tensioning force in relation to the set
tensioning force is displayed.
The tensioning process is completed
when the status indicator bar is complete-
ly filled.
► The tensioning button (6) can now be re-
leased.
► Press the sealing button (7) with the thumb of
your right hand until the seal is notched and
the strap is cut off.
If the operating lever is pulled too ear-
ly, the display appears orange with
error code and pulsating acoustic
signal (Section 6.7).
During the sealing of the seal the filled-in
dots of the status indicator light up in
sequence and then go out again.
The end of the sealing process is indi-
cated by an acoustic signal and green
control panel.