4.3
Setting strap tension
The set tension force is displayed continuously when the tool is ready for operation.
► Press "Tension force" button (2).
–
The set tension force flashes for 5 sec-
onds.
–
The + (1) and – (3) buttons appear.
–
Unused displays disappear.
► Press the + (1) or – (3) button until the desired
tension force is displayed.
–
The status indicator bar (4) shows the set
tension force in relation to the possible
maximum value.
► Save: Press the "Tension force" button (2) or
wait for 5 seconds.
●
Switch between display in "N" or "lbf": Press the flashing "Tension force" button (2) for
two seconds.
●
Every time the button is pressed an acoustic signal confirms the action.
●
The tension force is displayed continuously when the tool is operational.
●
Setting soft tension (Section 4.4).
BPT-H32:
N*
2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 7500
lbf*
(rounded values)
* N = Newton, lbf = pound-force per square inch
4.4
Switching touch-pad lock on and off
The touch pad can be locked to prevent unwanted changing of the settings.
► Locking: Press button "touch-pad lock" (1) for
approx. 2 seconds.
–
The lock symbol (2) and the first digit (3)
of the display flashes.
–
Unused displays are blanked out. Only
the +/– buttons and the lock symbol are
displayed.
► Press the + or – button until the first digit
indicates the desired value.
► Press the middle button to change to the next
digit.
► Repeat the procedure until the desired four-
digit code is displayed (factory setting 5878).
► Press the middle button.
–
The touch-pad lock is now on, the lock
symbol (4) changes position and is shown
closed.
► Unlocking: Unlocking is done in the same
order as described above.
38 of 50
1
2
3
440
550
660
770
3
4
5
6
7
880
990 1100 1210 1320 1430 1540 1650
3
SIGNODE BPT-H32
4
2
8
9
10
11
1
12
2
1
4
V 11.21_EN