Herunterladen Diese Seite drucken

Atlas Copco EP 7PTX-55 HR10-RE Produktanweisungen Seite 21

Vorschau ausblenden Andere Handbücher für EP 7PTX-55 HR10-RE:

Werbung

EP7PTX55 HR10-RE
Trouble shooting schedule
Troubleshooting - Trim / RE
Fault
The preset torque is decreasing and
the pulse frequency is slightly in-
creasing
The machine does not reach the ex-
pected torque
The machine does not shut off
Pulse frequency too low or too high Incorrect oil volume in pulse unit ? Refill oil
Accuracy not as good as expected
EN
Cause
Low oil level in the pulse unit?
Too soft joint ?
The yield point of the joint's screw
has been reached ?
Air pressure at the machine too
low ?
Torque adjusting screw is set in a
too deep position ?
Stop pin is not correct ly adjusted ?
Incorrect oil volume in pulse unit ?
Too soft joint ?
Too low rotary speed ?
Very hard joint and min. torque
setting ?
Too soft joint and max. torque set-
ting ?
Stop pin is not correctly adjusted ?
© Atlas Copco Industrial Technique AB - 9836 950700 00
Service instructions
Remedy
Refill oil
Operating area. A bigger machine?
Check the torque adjustment and
the joint's screw quality
Check the dimension of the hose
and coupling, increase air pressure
Adjust counter clockwise until the
shut off is distinct
Adjust according to the instruction
Refill oil
Choose a bigger machine
Check the Trim valve setting,
check the vane motor assembly
Lower free speed by the Trim
valve, Operating area
Check the Trim valve setting.
Choose a bigger machine, see Op-
erating area
Adjust according to the instruc-
tions.
21

Werbung

loading

Diese Anleitung auch für:

8431 0375 30