AWG | Fittings | Inductors Z2, Z4 and Z8
6 .2
Performing the inspection
CAUTION
Performing the inspection safely
Some inspection steps are performed with pressurised systems.
– Observe the safety regulations.
– Wear personal protective equipment.
– Do not put other persons in danger.
6 .2 .1
BASIC Inspection after each use
1. Inspect the inductor for visible damage.
2. Check the pick tube (accessory) for contamination and damage.
6 .2 .2
STANDARD Inspection every 12 months
1. Leak test at 10 bar inlet pressure.
6 .2 .3
ADVANCED Inspection every 12 months
>
Check the coupling torque of the Storz adapter:
Threshold value Storz 52 (C): 1.5 Nm
If the coupling torque is below the applicable threshold value,
the adapter must be replaced.
>
Threaded version: Check the thread for heavy wear and tear.
Replace device if worn.
37
Storz 75 (C): 2.5 Nm
functional tESt
M1061B10 | Rev. 03-08/24