Herunterladen Diese Seite drucken

Key Automation ALT3 Anleitungen Und Hinweise Zu Installation Und Einsatz Seite 47

Antrieb für schrankenanlagen mit baumlänge von 3 bis 8 m

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 114
6.10.2 CT10324F – BASIC MENU (BASIC)
CT10324F
CT10224F
1
2
3
4
5
6
7
8
9
10
11
OLD
TCL
Automatic reclosure time (0 = off)
ttr
Reclosing time after transit on PH1 (0 = off)
Sensitivity to obstacles
SEI
0 = Maximum impact force
10 = Minimum impact force
Opening rod speed
SFO
1 = minimum speed
5 = maximum speed
Closing rod speed
SFC
1 = minimum speed
5 = maximum speed
Defines the operating mode of the
STEP-BY-STEP SBS control
0 = normal AP-ST-CH-ST-AP-ST..
1 = alternating STOP AP-ST-CH-AP-ST-CH...
2 = alternating AP-CH-AP-CH...
3 = condominium mode 1; from the open position, the
closing manoeuvre time starts when the automatic
SBS
re-closure timer runs out
NOTE: the closing manoeuvre does not take place if
4 = condominium 2; an SBS command executes the
closing manoeuvre only if the rod is in the open
position.
PAR partial input configuration
0 = not available
1 = STOP NO
2 = STOP NC
3 = EDGE NC opening only
4 = 8k2 EDGE opening only
5 = 4k1 EDGE (two safety edges in parallel) opening only
ST2
ATTENTION !
= 0 (in the ADV menu)
ATTENTION !
opening safety edge, its intervention results in a
short reversal manoeuvre.
NOTE: there is no deactivation of ST2 with dip switch
Deceleration distance
LSI
40 to 100 = Motor deceleration percentage during opening
P= customized decelerations
Deceleration distance
LSI
40 to 100 = Motor deceleration percentage during closure
Post blackout procedure
BlT
0 = No action, remains stationery
1 = Closure
If active, in closed position, it disables the PHPOW power
SBY
supply
DESCRIPTION
= 0
if ST2 = 3/4/5, then set
if ST2 = 3/4/5 is used as an
DEFAULT MIN
MAX
0
0
900
0
0
30
3
0
10
5
1
5
5
1
5
4
0
4
0
0
5
55
40
100
58
40
100
0
0
1
0
0
1
EN
UNIT
s
s
%
%
47

Werbung

loading

Diese Anleitung auch für:

Alt4Alt6