6.10.1 - CT10324 - BASIC MENU (BASIC)
CT10324
1
2
3
4
5
6
7
8
9
10
11
12
46
OLD
CT10224
TCL
Automatic reclosure time (0 = off)
ttr
Reclosing time after transit on PH1 (0 = off)
Sensitivity on obstacles
SEI
0 = Maximum impact force
10 = Minimum impact force
Opening rod speed
SFO
1 = minimum speed
5 = maximum speed
Rod speed during the opening deceleration stage
SSO
1 = minimum speed
5 = maximum speed
Closing rod speed
SFC
1 = minimum speed
5 = maximum speed
Rod speed during the closing deceleration stage
SSC
1 = minimum speed
5 = maximum speed
Defines the operating mode of the SBS STEP-BY-STEP
command
0 = normal AP-ST-CH-ST-AP-ST..
1 = alternating STOP AP-ST-CH-AP-ST-CH...
2 = alternating AP-CH-AP-CH...
3 = condominium mode 1; from the open position, the
closing manoeuvre starts when the re-closure timer
SBS
runs out
NOTE: the closing manoeuvre does not take place if
4 = condominium 2; an SBS command executes the
closing manoeuvre only if the rod is in the open
position.
PAR partial input configuration
0 = not available
1 = STOP NO
2 = STOP NC
3 = EDGE NC opening only
4 = 8k2 EDGE opening only
5 = EDGE 4k1 (two safety edges in parallel) opening only
ST2
ATTENTION !
= 0 (in the
ATTENTION !
an opening safety edge, its intervention results in a
short reversal manoeuvre.
NOTE: there is no deactivation of ST2 with dip switch
Deceleration distance
1 to 100 = Motor deceleration percentage during
LSI
opening and closure
P= customized decelerations
Post blackout procedure
BlT
0 = No action, remains stationery
1 = Closure
Energy saving: enables photocell switch-off when bar-
rier is closed (only during this function PHOTOTEST is
SBY
not possible)
0= disabled
1= enabled
DESCRIPTION
= 0
if
= 3/4/5, then set
menu)
if
= 3/4/5 is used as
DEFAULT
MIN
MAX
0
0
900
0
0
30
3
0
10
4
1
5
1
1
5
4
1
5
1
1
5
4
0
4
0
0
5
20
1
100
0
0
1
0
0
1
UNIT
s