Installation:

Fit the flush-mounted box at a height of ca. 60 cm, 50 or 70 cm in front of the
GB
urinal wall in such a way that the front edge is level with the plastering.
R24
AS 1/2"
AS 3/4"
R24
AS 1/2"
AS 3/4"
The distance to the opposite wall can be adjusted on the setting regulator
(left stop 2 m, right 6 m)
Please ensure that tiling and joints in the area of the SanTec R 24
Mains
L
230 V
N
50 Hz
yellow/green
PE
Magnetic valve
L
230 V
N
50 Hz
yellow/green
PE
Attach the reflector to the opposite wall. While doing so observe the small pilot
lamp in the red sensor cover of the R 24: If it goes out it means that the emitted
infrared light is being reflected. Proceed in this way to determine the area hit by
the light beam of the device; subsequently install the reflector in the middle of
that area.
With the rotary controller it is possible to continuously adjust the flushing time
from 1 second (right stop) to 10 seconds (left stop).
Attention when conducting the operational test:
The control doesn't flush in the first 30 s after initiation.
Pre- and after-flushing:
After-flushing only:
are in keeping with applicable standards!
brown
blue
brown
blue
Mount the SanTec R24 ca. 70 cm in front of
the urinal wall, so that the imaginary sensor
line is crosed on approach.
Mount the SanTec R24 ca. 50 cm in front of
the urinal wall, so that the imaginary sensor
line is interrupted during use.
First connect the valve set then connect to the
mains system (this must be done by a regi-
stered specialist)!