Fig. 7: Plugging in the 3-contact connector pair again
The initial start-up procedure is complete.
STARTUP
These functions are only to be carried out when the Mammut system is activated for the first time after
installation, or when a new remote control is being put into operation.
Initial start-up after delivery of the new system is generally performed by the specialist workshop which
has installed the drive units.
CAUTION!
Danger due to incorrect programming!
Errors during initial start-up can lead to misinterpretations between the remote control and the
controller. This can result in hazardous operating situations.
Carry out initial start-up on open ground, so that you can subsequently carry out a test run and
function test with sufficient distance between you and the caravan.
To avoid the possibility of transmission errors, you should not perform initial start-up in the direct
vicinity of another caravan with Mammut drives.
Selecting the operating mode
Only required if the Caravan does not rotate on the position.
1. Switch on the remote control as per section „Calibrating the remote control and system", step 1-5.
2. Check the LED displays.
3. If both LEDs „Maximum climbing power" and „Maximum drive temperature" light up, then press but-
tons d and g one time simultaneously.
The „Maximum climbing power" LED goes out.
The „Maximum drive temperature" LED stays lit.
4. Switch off the remote control.
The remote control is now in operating mode 1, the Caravan can now rotate on the position.
Should you have any questions or require clarification of any points, please contact our AL-KO
Service or your installation workshop.
MANUAL RETRACTION IN CASE OF MALFUNCTION
If a drive can no longer be moved away from the wheel with the remote control, it can be retracted from
the tyre using the manual retraction function.