Motor connection

{
Danger!
All control terminals only have basic insulation (single isolating distance)
ƒ
after connecting a PTC thermistor or a thermal contact.
Protection against accidental contact in case of a defective isolating
ƒ
distance is only guaranteed through external measures, e. g. double
insulation.
0.5...0.6 Nm
4.4...5.3 lb-in
0.5...0.6 Nm
4.4...5.3 lb-in
3.4 Nm
30 lb-in
8200mot008
T1,T2 Terminals of motor temperature monitoring with PTC thermistor (PTC) or thermal contact (NC
contact).
Activate motor temperature monitoring with C0119 (e.g. C0119 = 1)!
EDK82MV222 DE/EN/FR 11.0
X2
T1 T2
2
2
2.5 mm
2.5 mm
T2
T2
T1
T1
AWG 12
AWG 12
6mm
6mm
PE
J >
J >
X2
Fig. 4−5
1a
l
Mechanical installation
Motor mounting
W2 U2
PE W
V U
U1
1a
V2
V1 W1 PE
3.4 Nm
30 lb-in
4