Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Cooling
Outdoor temperature
operation
Room temperature
CAUTION
Dry operation
Outdoor temperature
Room temperature
Heating
Outdoor temperature
operation
Room temperature
If air conditioner is used outside of the above conditions, safety protection may work.

RE-INSTALLATION

Ask the dealer or an installation professional to re-install the air conditioner to a new place or
move it to another place and to observe the following items.
If the air conditioner is inappropriate installed by yourself, it may cause electric shock or fire.

Do not install the air conditioner in the following places

• Do not install the air conditioner in any place within 1 m from a TV, stereo, or radio set. If the unit is installed
in such place, noise transmitted from the air conditioner affects the operation of these appliances.
• Do not install the air conditioner near a high frequency appliance (sewing machine or massager for business
use, etc.), otherwise the air conditioner may malfunction.
• Do not install the air conditioner in a humid or oily place, or in a place where steam, soot, or corrosive gas is
generated.
• Do not install the air conditioner in a salty place such as seaside area.
• Do not install the air conditioner in a place where a great deal of machine oil is used.
• Do not install the air conditioner in a place where it is usually exposed to strong wind such as in seaside
area or on the roof or upper floor of a building.
• Do not install the air conditioner in a place where sulfureous gas generated such as in a spa.
• Do not install the air conditioner in a vessel or mobile crane.
Be careful with noise or vibrations
• Do not install the air conditioner in a place where noise by outdoor unit or hot air from its air outlet annoys
your neighbors.
• Install the air conditioner on a solid and stable foundation so that it prevents transmission of resonating,
operation noise and vibration.
• If one indoor unit is operating, some sound may be audible from other indoor units that are not operating.
: –5°C to 43°C
: 21°C to 32°C (Dry valve temp.), 15°C to 24°C (Wet valve temp.)
Room relative humidity – less than 80 %. If the air conditioner operates
in excess of this figure, the surface of the air conditioner may cause dewing.
: 15°C to 43°C (Maximum suction air temp. 46°C)
: 17°C to 32°C
: –15°C to 15.5°C (Wet valve temp.)
: 15°C to 28°C (Dry valve temp.)
DANGER