Herunterladen Inhalt Inhalt Diese Seite drucken

Toshiba MMU-AP0091H Betriebsanleitung Seite 14

Vorschau ausblenden Andere Handbücher für MMU-AP0091H:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

According to the shape or arrangement of the room, the cold air and hot air can be discharged for two direc-
tions or three directions. For details, contact the dealer.
• If cooling operation is performed with downward discharge, dew may fall on surface of the cabinet or the
horizontal flap resulted in dripping.
• If heating operation is performed with horizontal discharge, unevenness of temperature may increase in
the room.
• Do not move the horizontal flap directly with hands; otherwise a trouble is caused. Select direction of the
horizontal flap using flap operation switch on the remote controller. The horizontal flap does not stop
immediately even if the switch is pushed. Adjusting the stop position, push the switch.
2-way Air Discharge Cassette Type
[In Cooling operation]
Use the air outlet flap with horizontal set point.
[In Heating operation (For Heat-pump model only)]
Use the air outlet flap with downward set point.
Setup of air direction and swinging
1
Push
button during operation.
• [SWING
] is displayed and the air direction automatically changes upward/downward.
In case when one remote controller controls the multiple indoor units, each indoor unit can be selected
and its air direction can be set up.
2
Push
button again during swinging of the air
outlet flapp.
• The air outlet flap can be stopped at the desired
position.
3
UNIT
• To set up the air direction individually, push
button to display each indoor unit No. in a group
control. Then set up the air direction to a displayed
indoor unit.
• If there is no display, all the indoor units can be oper-
ated collectively.
• Every pushing
as shown in the figure.
1-way Air Discharge Cassette Type
Adjustment of air direction upward/downward
[In Cooling operation]
In cooling operation, use the air outlet flap with horizontal set point so that the
cold air diffuses in whole room.
[In Heating operation (For Heat-pump model only)]
In heating operation, use the air outlet flap with downward set point so that
the hot air blows at the foot.
Adjustment of air direction rightward/leftward
To change the discharge direction to right or left side, set the vertical grille
inside of the air outlet flap to the desired direction.
Setup of air direction and swinging
Refer to description of "2-way Air Discharge Cassette Type".
INFORMATION
button, the display exchanges
UNIT
UNIT
No display
11
UNIT
SET
CL
1, 2
Unit No. 1-1
Unit No. 1-2
Unit No. 1-4
Unit No. 1-3
3

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis