Requirements For Use In Potentially Explosive Atmospheres - WIKA 700.02.080 Betriebsanleitung

Differenzdruckmessgeräte mit magnetkolben typ 700.0x nach richtlinie 94/9/eg (atex)
Vorschau ausblenden Andere Handbücher für 700.02.080:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

3. Technical data ... / 4. Requirements for use in potentially ...
Materials
Wetted parts:
GB
Dial and pointer:
Display housing:
Window:

4. Requirements for use in potentially explosive atmospheres

Operating temperature
Ambient: 0 ... +60 °C
Medium: The permissible medium temperature does not only depend on
the instrument design, but also on the ignition temperature of the
surrounding explosive atmosphere. Both aspects must be taken into
account.
Attention! In the case of gaseous substances, the temperature may increase
due to compression warming. In these cases it may be necessary to throttle the
rate of change of pressure or reduce the permissible temperature of the pressu-
re medium.
Permissible medium temperature
Temperature class of
the ambient atmosphere
(ignition temperature)
T 6 ( > 85 °C)
T 5 ( > 100 °C)
all other temperature classes
6
WIKA Operating instructions differential pressure gauges with piston per ATEX
Pressure chamber with connections: stainless steel
Pressure element: stainless steel
Magnetic piston: stainless steel, hard-ferrit
Separation diaphragm: NBR (only Model 700.02)
Aluminium
Aluminium, die-casting
Clear non-splintering plastic
Maximum permissible medium
temperature (in the pressure system)
+70 °C
+85 °C
+100 °C