13. Guarantee
This device is covered by a 5 year guarantee from the date of
purchase. During this guarantee period, at our discretion,
Microlife will repair or replace the defective product free of charge.
Opening or altering the device invalidates the guarantee.
The following items are excluded from the guarantee:
Transport costs and risks of transport.
Damage caused by incorrect application or non-compliance
with the instructions for use.
Damage caused by leaking batteries.
Damage caused by accident or misuse.
Packaging/storage material and instructions for use.
Regular checks and maintenance (calibration).
Accessories and wearing parts: Batteries, Probe cover
(optional).
Should guarantee service be required, please contact the dealer
from where the product was purchased, or your local Microlife
service. You may contact your local Microlife service through our
website: www.microlife.com/support
Compensation is limited to the value of the product. The guarantee
will be granted if the complete product is returned with the original
invoice. Repair or replacement within guarantee does not prolong
or renew the guarantee period. The legal claims and rights of
consumers are not limited by this guarantee.
14. Technical Specifications
Type:
Adjusted mode Non Contact
Thermometer NC 150
Mode type:
Adjust mode
Measuring site:
Forehead
Reference body site: Sublingual
Measurement range: Body mode: 34.0 - 43.0 °C /
93.2 - 109.4 °F
Object mode: 0.1 - 99.9 °C /
32.2 - 211.8 °F
Resolution:
0.1 °C / °F
Measurement accu-
0±.2 °C, 36.0 ~ 39.0 °C / ±0.4 °F,
racy (Laboratory):
96.8 ~ 102.2 °F
Microlife NC 150
Clinical results:
Repeatability: 0.09 °C
Bias: 0.06 °C
Limits of agreement: 0.54 °C
Display:
Liquid Crystal Display, 4 digits plus
special icons
Acoustic:
The unit is turned ON and ready for the
measurement: 1 short beep.
Complete the measurement: 1 long beep
(1 sec.) if the reading is less than 37.5 °C
/ 99.5 °F, 10 short «beep» sounds, if the
reading is equal to or greater than
37.5 °C / 99.5 °F.
System error or malfunction: 3 short «bi»
sounds.
Memory:
30 readings recall in the memory mode
with a record of both time and date.
Backlight:
The display light will be GREEN for
1 second, when the unit is turned ON.
The display light will be GREEN for 5
seconds, when a measurement is
completed with a reading less than
37.5 °C / 99.5 °F.
The display light will be RED for
5 seconds, when a measurement is
completed with a reading equal to or
higher than 37.5 °C / 99.5 °F.
Operating
Body mode: 15 - 40.0 °C / 59 - 104.0 °F
conditions:
Object mode: 5 - 40.0 °C / 41 - 104.0 °F
15 - 95 % relative maximum humidity
Storage conditions: -25 - +55 °C / -13 - +131 °F
15 - 95 % relative maximum humidity
Automatic
Approx. 1 minute after last measurement
Switch-off:
has been taken.
Battery:
2 x 1.5 V alkaline batteries; size AAA
Battery lifetime:
approx. 2000 measurements
(using new batteries)
Dimensions:
141.1 x 43.3 x 36.9 mm
Weight:
90 g (with batteries), 67 g (w/o batteries)
IP Class:
IP21
5