Herunterladen Diese Seite drucken

Microlife NC 150 Bedienungsanleitung Seite 4

Vorschau ausblenden Andere Handbücher für NC 150:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 27
body temperature or it also has a feature allowing it to be used to
measure surface temperature of the following examples:
 Milk surface temperature in a baby's bottle
 Surface temperature of a baby's bath
 Ambient temperature
Accurate and reliable
The unique probe assembly construction incorporates an
advanced infrared sensor, ensuring that each measurement is
accurate and reliable.
Gentle and easy to use
 The ergonomic design enables simple and easy use of the ther-
mometer.
 This thermometer can even be used on a sleeping child without
causing any interruption.
 This thermometer is quick, therefore child-friendly.
Multiple readings recall
Users will be able to recall the last 30 readings with a record
of both time and date when entering the recall mode, enabling
efficient tracking of temperature variations.
Safe and hygienic
 No direct skin contact.
 No risk of broken glass or mercury ingestion.
 Completely safe for use on children.
2. Important Safety Instructions
 Follow instructions for use. This document provides important
product operation and safety information regarding this device.
Please read this document thoroughly before using the device
and keep for future reference.
 This device may only be used for the purposes described in
these instructions. The manufacturer cannot be held liable for
damage caused by incorrect application.
 Never immerse this device in water or other liquids. For
cleaning please follow the instructions in the « Cleaning
and disinfecting» section.
 Do not use this device if you think it is damaged or notice
anything unusual.
 Never open this device.
 A basic physiological effect called vasoconstriction can occur in
the early stages of fever, resulting in a cool skin effect. The
recorded temperature using this thermometer can, therefore,
be unusually low.
2
 If the measurement result is not consistent with the patient's
finding or unusually low, repeat the measurement every 15
minutes or double check the result by another core body
temperature measurement.
 This device comprises sensitive components and must be
treated with caution. Observe the storage and operating condi-
tions described in the «Technical Specifications» section.
 Ensure that children do not use this device unsupervised; some
parts are small enough to be swallowed.
 Do not use this device close to strong electromagnetic fields such
as mobile telephones or radio installations. Keep a minimum
distance of 3.3 m from such devices when using this device.
 Protect it from:
 extreme temperatures
 impact and dropping
 contamination and dust
 direct sunlight
 heat and cold
 If the device is not going to be used for a prolonged period the
batteries should be removed.
WARNING: The measurement results given by this device
is not a diagnosis. It is not replacing the need for the consul-
tation of a physician, especially if not matching the patient's
symptoms. Do not rely on the measurement result only,
always consider other potentially occurring symptoms and
the patient's feedback. Calling a doctor or an ambulance is
advised if needed.
3. How this Thermometer measures Temperature
This thermometer measures infrared energy radiated from the
forehead as well as objects. This energy is collected through the
lens and converted to a temperature value.
4. Control Displays and Symbols
 All segments displayed 9: Press the ON/OFF button 5 to
turn on the unit; all segments will be shown for 1 second.
 Ready for measuring AK: When the unit is ready for
measuring, the «°C» or «°F» icon will keep flashing while the
mode icon (body or object) will be displayed.
 Measurement complete AL: The reading will be shown on the
display 3 with the «°C» or «°F» icon and the mode icon

Werbung