TROUBLE SHOOTING
Problem
Motor will not start.
The motor stops directly
after starting.
Pump runs but no suction.
Pump runs but poor suction.
Machine blows dust.
Abnormal sound from
machine.
2014-10-23
the machine is used under normal conditions and that
proper maintenance has been performed. Normal wear on
the machine is not covered by the warranty.
If other than Dustcontrol or Dustcontrol authorized person-
nel attempt repair, this warranty is null and void.
Fault
Machine not connected.
Thermal overload tripped.
Starter is incorrectly
connected.
Incorrect fuse.
Thermal overload not set
correctly.
Hose not connected.
Hose or tubing system is
No plastic sack on the
cyclone.
Pump rotation backwards.
Shutter on the cyclone inlet
is closed.
Hole in the hose.
Leakage in the tubing
system
Plugged fi lter.
Hose too long or too small.
Hose is kinked.
Machine top is mounted
incorrectly.
Dust is packed in the
cyclone.
Filter is perforated or has
come loose.
Particles in the pump.
DC 3800 Stat - 11
Solution
Make sure connection.
Wait 5 minutes.
Call an electrician.
Change to correct circuit.
Electrician should adjust.
Connect the hose.
Locate and remove
plugged.
blockage.
Mount the correct sack.
Electrician should change
phases.
Open it.
Change or repair hose.
Check tubing and joints.
Clean or change fi lter.
Change the hose.
Check and free.
Adjust the mounting.
Take off the top and clean
out.
Check the fi lters and change
if necessary.
Order service.
Part No 9443