Operation
Th e fi ne fi lter should be cleaned at least once or twice per
day with continuous operation.
Procedure:
1.
Start the unit.
2.
Close the shutter on the
3.
Open and shut the cleaning fl ap with quick
movement 8-10 times.
4.
Open the shutter on the cyclone inlet.
Service
During cleaning and maintenance of the unit, the discon-
nect should be locked out.
Filter Change
Th e fi ne fi lter should be changed at least once per year. Use
only original spare parts. Use breathing protection when
changing the fi lter.
*
Shut off the electrical disconnect.
*
Wear breathing protection.
*
Ensure that no unprotected persons can be
exposed to the dust.
*
Loosen the eccentric locks that secure the top
of the cyclone unit.
*
Lift off the top.
*
Lift out the fi ne fi lter and seal it in a plastic
sack for correct disposal.
*
Install the new fi ne fi lter on the bayonet mount,
Accessories
Description
Plastic sack, standard 50 pcs 4110
Fine fi lter:
polyester, standard
cellulose, class "C"
cyclone inlet.
Part No
42025
42026
DC 3800 Stat - 10
5.
If the suction has returned to normal, use of the
unit can resume. If the suction is not normal,
cleaning should be repeated. If repeated clea
ning fails to return normal suction, a change of
the fi ne fi lter may be necessary.
Th e plastic sack should be changed after fi lter cleaning. It
should be changed when the level of material in the sack is 5
cm under the foot valve. Th e plastic sack must be sealed after
removal from the machine. Use only original spare parts.
replace in the machine and secure the top.
If the machine is equipped with a HEPA fi lter, this should
be changed after approximately 300 running hours.
Th e DC 3800 Stationary should be performance tested and
inspected for correct function at least once per year because
it may be used on hazardous dusts. Worn parts should be
replaced.
Always use original spare parts.
Th e turbopump has a very long maintenance free service
life. After approximately 10 000 running hours, the radial
seal between the motor and pump housing should be
greased. Bearings and seals in the motor and turbopump
should be checked and lubricated. Parts worn beyond
serviceable tolerances should be replaced with genuine
spare parts.
Description
Microfi lter
Other accessories — see Dustcontrol catalogue.
Part No
42024
Part No 9443