E Specifications: surface mounted unit
Hydraulic:
Flow rate: 19l/min at 3bar; noice category 1 with resistance class B;
(29l/min at free outlet)
recomended Flow pressure
working pressure
Testing pressure
recomended Hot water temperature
max. adjustable Temperatur
Electrical:
LCD display
Power supply using standard batteries (four 1.5 V LR 14 batteries)
We recommend high-quality mercury- and cadium-free alkaline
batteries IEC designation: LR 14, US/UK designation: C
EC Declaration of Conformity
as per Article 10.1
of Directive 89/336/EEC (EMC Directive)
We,
Ideal Standard GmbH
Roentgenstrasse 9
D-54156 Wittlich
Germany
Name and address of the manufacture or the party registered in
the EU and bringing the product into circulation
declare at our sole responsibility that the product
Tub and shower unit
EBC
to which this Declaration refers, conforms to the following standards/
standardising documents:
1. EN 55 014:1993
2. EN 50 081:1992
3. EN 50 082:1992
4. EN 55 104:1995
This Declaration is based on the following:
Test report issued by TÜV Rheinland Product Safety GmbH, 51101
Cologne, Germany
No. P 9710 215 EO1
_________________________________________________________________
_________________________________________________________________
Name, address, date and signature of the person who is legally responsible
1-5 bar
max. 6 bar
16 bar
50-65 °C
48 °C
(emitted interference EMA)
(emitted interference EMA)
(immunity to interference EMB)
(immunity to interference EMB)
Page 23