4.2 Prerequisites for use
The PC on which the test software is to be installed
must meet the following minimum requirements:
– Processor: 1.6 GHz or higher
– RAM: 2 GB or larger
– Free disk space: >500 MB
– Operating system: Windows 10 or later
– 1 free USB port (Quaestor 4000/6000)
– 2 free USB ports (Quaestor 8000)
4.3 Prior to first use
Before the test unit can be put into operation, the
following steps must be carried out:
1. Install the test software on the PC and create the
data (see "Install the test software", page 17).
2. If applicable, fit accessories to the test unit.
3. Set up the test unit (see "Setting up the test unit",
page 18).
4.3.1 Install the test software
For installation, the user must have administrator
rights for the PC.
1. Download the latest version of the Protector
Software from www.draeger.com/software and start
the setup file.
2. Follow the instructions in the setup program. The
required program components will be installed in the
selected folder and an entry for the program will be
created in the start menu.
3. Observe the information displayed during
installation.
4. Restart the PC and log in.
The following users are available on delivery of
the test software:
– The user "Chief" with the password "Createdata"
– The user "admin" with the password "admin"
Information about the test software is available on
the help pages.
5. If necessary, create additional user accounts for use
with the test software as well as entering details on
breathing safety products, customers and locations
(see "First steps" on the help pages of the Protector
Software (F1)).
Instructions for use
|
Dräger Quaestor 4000/6000/8000
4.3.2 Fitting the brackets for the pressure
gauge or Bodyguard (Dräger
Quaestor 8000 only)
● Fit the bracket on the right or left under the test unit
with the two screws supplied.
4.3.3 Connecting the microphone (Dräger
Quaestor 8000 only)
1. Connect the supplied USB microphone to the PC.
2. Select and save the USB microphone in the test
software under Extras > Settings > Gauge
accuracy test.
3. Position the microphone near the warning device.
4.3.4 Fitting the adapter for mask/helmet
combinations
1. Use the drill supplied to drill a hole at each of the
points marked on the test head.
The top of the test head is approx. 5 mm thick; the
test head itself is hollow on the inside. The interior of
the test head cannot be damaged by the drilling.
Commissioning the test unit
|
17