Herunterladen Diese Seite drucken

V-ZUG V200 Installationsanleitung Seite 65

Kühl- und gefriergerät
Vorschau ausblenden Andere Handbücher für V200:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

-
The body of the unit should be at least 16 mm thick but
not more than 19 mm.
-
When mounting a 2-door cabinet door, observe the
recommended clearances.
Fig. 66 Clearances for a 2-door cabinet door
Recess height 178-2 drawers
Appliance height (A) ( mm)
Distance (B) ( mm)
Clearance (C) door-on-door ( mm) 549+15 (21 5/8 + 5/8)
Recess height 178-3 drawers
Appliance height (A) ( mm)
Distance (B) ( mm)
Clearance (C) door-on-door ( mm) 695+15 (27 3/8 + 5/8)
Other cabinet door above, below or next to it:
The vertical gap between custom panels must be 4 mm.
-
-
The horizontal gap between custom panels must
be 4 mm. Check the risk of them clashing here.
(see 15.3 Setting the clearance to avoid collision)
Weight and hinges:
Heavy cabinet fronts increase the stress on the hinge.
-
The hinge may be damaged. As such, refer to the cata‐
logue for the maximum weight specification for your
appliance.
-
If the cabinet front exceeds the maximum permitted
weight, an appliance with door-tracking device can help
by loading the weight over several concealed hinges on
the cabinet.
If you use long unit fronts that protrude far above the
-
appliances, we recommend an additional door hinge (e.g.
Kamat), which must have the same pivot point as the
fixed door hinge used with your appliance. By using
another hinge (Kamat), the weight is shared over several
points. The use of a milled compensating fastening is
recommended for high unit fronts to counteract warping
(convex/concave).
* Depending on model and options
15.2 Mounting the cabinet front(s)
When installing, note:
- Cabinet front must be installed symmetrically to the
- Adjoining cabinet front is exactly level.
- Adjoining cabinet front has the same edge radius as the
- Cabinet front is flat and tension-free.
- The front panel has a minimum depth setting of approx.
u Install the appliance in the recess.
u Fasten the front panel to the appliance door.
u Check that the front panel can close unobstructed.
15.3 Setting the clearance to avoid colli‐
sion
After installing the cabinet front(s), check that the cabinet
fronts do not collide.
 1770
 15
 1770
 15
Fig. 67
Fig. 68 Table of clearance limits
G
G
Note
When making adjustments, always make sure that the
cabinet front suits the general appearance.
Check the collision factors and adjust them accordingly:
refrigerator door.
front of the appliance.
2 mm to the body.
(see 15.3 Setting the clearance to avoid collision)
(1) Front thickness (FD)
(2) Edge radius (R)
= min. clearance in mm
min
= max. clearance in mm
max
Cabinet fronts
(3) Clearance (S)
65

Werbung

loading

Diese Anleitung auch für:

V600V2000V4000