Ventilation requirements
u Align the cabinets with a spirit level and a try square. If
necessary, level them by putting something underneath
them.
u Make sure that the floor and the side panels of the
cabinet are at 90° to each other.
5 Ventilation requirements
NOTICE
Covered vents!
Damage. Appliance can overheat, which can reduce the
service life of various parts of the appliance and lead to
operational impairments.
u Always make sure there is good ventilation.
u Always keep vents or ventilation grids in the appliance
housing and in the kitchen furniture (fully integrated
appliance) unobstructed.
u Always keep the fan air vents unobstructed.
Always follow the required ventilation gaps:
The depth of the ventilation shaft at the back of the
-
cabinet must be at least 38 mm.
-
At least 200 cm
2
is required for the ventilation gap cross
sections in the plinth and the housing cabinet.
As a rule, the larger the ventilation cross-section, the
-
more efficiently the appliance will run.
Sufficient ventilation is required for the operation of the
appliance. The ventilation grids provided ensure an effec‐
tive ventilation cross-section on the appliance of 200 cm
If you replace the ventilation grids with a cover plate the
ventilation cross-section must be as least as large as the
ventilation grid provided by the manufacturer.
6 Custom panel weights
6.1 Weight
NOTICE
An excessively heavy custom panel can potentially cause
damage!
If the custom panel is too heavy, damage to the hinges
cannot be ruled out, which may compromise the function‐
ality of the unit.
u Before fitting the custom panel, ensure that the custom
panel does not exceed the permissible weight.
Niche
height
Appliance type Maximum
(mm)
880
Cooler V600
Cooler V200
1220
Cooler V2000
Cooler V600
1780
Freezer V4000
Cooler V4000
Single-door fridges and freezers
7 Transporting appliance
u On initial setup: Transport the appliance in its packaging.
u When transporting after initial setup (e.g. relocation):
Transport the appliance unloaded.
u Transport the appliance upright.
u Use two people to transport the appliance.
54
2
.
weight
of
custom panel (kg)
16
19
26
8 Unpacking the appliance
Before you connect the appliance, report any damage imme‐
diately to the delivery company.
u Check the appliance and the packaging for damage
during transport. Contact the supplier immediately if you
suspect any level of damage.
u Remove all materials from the back or the side walls
of the appliance that may prevent proper installation or
ventilation.
u Remove all protective films from the appliance. Do not
use sharp or pointed objects for this.
u Take the power cable from the rear of the appliance.
Remove the cable brackets when you do this, otherwise
there will be noise caused by vibrations!
9 Setting up the appliance
CAUTION
Risk of injury due to heavy appliance!
u Have two people transport the appliance to its installa‐
tion site.
WARNING
Danger of injury and damage due to the appliance being
unstable!
The appliance can topple over.
u Secure the appliance as described in the instructions.
WARNING
Fire hazard and danger of damage!
u Do not place appliances emitting heat e.g. microwaves,
toasters etc. on the appliance!
If possible, have the appliance installed in the kitchen unit
by a professional.
Do not install the appliance on your own.
9.1 After installation
u Remove all transport safety components.
Fig. 4
u Pull off the transport lock
on the appliance door.
u Clean the appliance (see User Guide, Cleaning the appli‐
ance).
* Depending on model and options
*