Adjustment method
Obtain minimum
peak
—- peak
|
value of waveform
by turning
R1547 and R1440.
Adjustment position
Adjustment condition
. The same as in white balance .
2. Connect CH2 of socilloscope to pin
(8) of B connector (B-OUT).
3. Reverse waveform of CH1, and add
CH1 and CH2 (ADD mode).
4. After
step
white
balance
adjustment Red and Blue, you may
have to performed
fine using
controls R1440 and R1547.
White balance adjustment
(Blue)
-] R1547:
Blue Drive
[]R1440:
Blue Bias
Inside sensor board
Connect
Q3005
base to GND,and
force DC fan to rotate at a high speed.
Connect a digital voltmeter to fan
supply terminal voltage position (I1).
If Q3005 base is connected to GND
high fan speed is obtained and low
speed if itis connected to Vcc + 12V.
Fan switching voltage
setting control
(R3039)
Set the voltage of (11) within
13V+0.1V
using
control
of
R3039.
1. Receive
"PAL
COLOUR
BAR"
signal.
2. Connect an ascilloscope as shown
below.
PAL chroma adjustment
[1 R803:
1H-delay amp.
control
LI T802:
1H-delay phase
control
L1T801:
CW phase control
To oscilloscope
_ Press the $2112 Video STANDARD
|
switch (Reset).
T802
Adjust the colour control so that
the colour
difference
signal
becomes 2.5Vp-p. See the above
figure.
. Receive "SECAM
COLOUR
BAR"
signal.
2. Connect the oscilloscope between
TP931 and GND.
Bell filter adjustment:
(7931)
R and Bto be at the same amplitude
W
W
RB
RB
Adjust T931 so that the red and
blue outputs
have the same
amplitude.
15