Herunterladen Diese Seite drucken

Victron energy PIN483020000 Anleitung Seite 21

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 65
8. TECHNICAL SPECIFICATIONS
Phoenix Inverter
INVERTER
Input voltage range (V DC)
Output
(1)
Cont. output power at 25°C (VA)
Cont. output power at 25°C (W)
Cont. output power at 40°C (W)
Cont. output power at 65°C (W)
Peak power (W)
Maximum efficiency (%)
Zero-load power (W)
GENERAL
4Protection
(2)
Common Characteristics
ENCLOSURE
Common Characteristics
Battery-connection
230 V AC-connection
Weight (kg)
Dimensions (hxwxd in mm)
STANDARDS
Safety
Emission / Immunity
Automotive Directive
1) Can be adjusted to 60Hz; 120V/60Hz on request
2) Protection
a. Output short circuit
b. Overload
c. Battery voltage too high
d. Battery voltage too low
e. Temperature too high
f. 230VAC on inverter output
g. Input voltage ripple too high
3) Non linear load, crest factor 3:1
4) Multipurpose relay which can be set for general alarm, DC undervoltage or genset start signal
function
12/3000
9,5 – 17
Output voltage: 230VAC ± 2%
3000
(3)
2500
2200
1700
6000
92
20
Operating temp.: -40 to +65°C (fan assisted cooling)
Humidity (non condensing): max 95%
Material & Colour: aluminium (blue RAL 5012) Protection: IP 21
M8 bolts (2 plus and 2 minus connections)
Screw terminals 13mm² (6 AWG)
EN 60335-1, EN 60335-2-29
EN 55014-1, EN 61000-3-2 / EN 55014-2, EN 61000-3-3
24/3000
19 – 33
Frequency
50Hz ± 0,1%
:
3000
2500
2200
1700
6000
94
20
a - g
18
362x258x218
2004/104/EC
48/3000
38 – 66
3000
2500
2200
1700
6000
95
25
19

Werbung

loading