freely rotates.
Visual tension indicator (Figure 3) – This component allows the
User to check the system tension in situations where it is impractical
to reach a tension indicator disc from a position of safety.
VLL system label - Check the product label, all regulatory
information (installation date, ID, max. users, system type and
inspection date) shall be clearly legible.
Complete the Latchways GTFA Pre use checks in accordance
with Table 2.
Inspect the system for any excessive wear, damage or corrosion
and evidence that it is within its service life. Ensure that the device
is compatible with the system and sufficient energy absorption is
provided (p 118- Latchways VLL system label).
If the Latchways GTFA does not pass any of the pre-use
checks, it shall be immediately withdrawn from service. This
shall be recorded on the record card and the device passed to a
1
Technician
for disposal or repair.
7 User Instructions
1. Hold the Latchways GTFA in the right hand by the release
catch cover below the level of the attachment point so that the
linkage is in the vertical plane. This will force the cam into the
unlocked position. Figure 4.
2. Press the release catch with your right thumb. The release
catch will not operate if the device is incorrectly oriented. Using
your left hand pull the Star wheel away from the body of the
device and offer the device up to the cable. Figure 5.
3. M ove the device around the cable until the cable is held within
the cavity in the body of the device. Remove your thumb and
allow the release catch to return. Finally allow the star wheel
to move back into its original position, check that the release
catch has disengaged and the star wheel cannot be pulled out.
Figure 6.
7