8.
MAINTENANCE
Before starting maintenance work, all on-site shut-offs in front of and behind the
CLEAR PRO KD or the CLEAR PRO K must be closed. In addition, pressure relief is always
required.
Also the shut-off of the filter must be closed, as described below.
8.1 Manal shut-off
Fig. 8.1: Release the flap [a] by pressing lightly on the two snap hooks [b] on the outer edge.
/
Remove the flap.
The handle [c] is now freely accessible. It is used to manually shut off the CLEAR PRO KD
/
cartridge filter and the CLEAR PRO K cartridge filter.
Fig. 8.2: Turn the handle [c] 90° in the direction of the arrow until it stops.
/
Fig. 8.3: The manual shut-off is closed.
/
[b]
[a]
[c]
Fig. 8.1
8.2 Leakage protection (optional)
Optionally, the manual shut-off can be replaced by the retrofit
leakage protection CLEAR PRO CONEL MultiControl for filters
3/4" - 1 1/4", CLEARPNLS, (Fig. 9.4).
With this system, the function of the shut-off is taken over fully
automatically by the controller.
The retrofit leakage protection CLEAR PRO CONEL measures
the flow by means of a turbine with an upstream resistor.
[c]
Fig. 8.2
[c]
Fig. 8.3
17
Fig. 8.4