6.2 Mounting CLEAR PRO KD cartridge filter / CLEAR PRO K cartridge filter
Note that the main axis is aligned vertically (Fig. 6.3)
Installation may only be carried out by suitable qualified personnel.
Move the filter towards the flange in the
/
direction of the arrow [a] and position it
tighten the hexagon socket screws
/
M6 x 25 [b] with the hexagon socket
spanner [c] in the direction of the arrow
in alternating crosswise sequence
make sure that the flange gasket [d] is
/
seated correctly
The tightening torque is approx. 6 Nm.
It has to be chosen in such a way that
the seal closes but the filter is not
damaged or put under tension.
7.
SETTING OUTPUT PRESSURE
The outlet pressure of the CLEAR PRO KD cartridge filter is
preset at the factory to 4 bar and can be adjusted in the range
from 1.5 to 6 bar as follows:
ensure that the inlet pressure is at least 1 bar higher than
/
the desired output pressure
loosen plug [a] carefully: lever under the notch, remove
/
plug [a] (Fig. 7.1)
position the hexagon socket spanner in the hexagon
/
socket of the set screw
Pressure increase: turn clockwise in the direction of the
/
arrow (fig. 7.2) = increase pressure (+) with constant
visual control of the manometer
Pressure minimisation: turn counterclockwise in the
/
direction of the arrow (Fig. 7.2) = minimise pressure (-)
Open an adjacent tap downstream of the filter, take a
/
small amount of water, then close it again
visual check of the pressure gauge display
/
depending on the display: Repeat the „Pressure
/
minimisation" procedure or start again at the „Pressure
increase" point
[c]
[b]
[d]
[a]
Fig. 6.3
[a]
Fig. 7.1
Fig. 7.2