Herunterladen Diese Seite drucken

Dik Geurts Instyle 700 Installationsvorschrift Seite 42

Vorschau ausblenden Andere Handbücher für Instyle 700:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

9.7.2.2 Outside air connection
It is possible to provide the appliance with an outside air connection. This outside air connection is optionally
available (as an external kit). This kit can be used for a connection on the bottom of the appliance and is available
through your supplier.
It is possible that the outside air connection is pre-mounted at delivery. This will be the case for an RS (room
!Caution
sealed) version. Observe the steps as described under the heading 'Outside air connection pre-mounted'.
When assembling the outside air connection, proceed as follows:
Outside air connection not pre-mounted (see appendix 2, fig. 21):
Ø
Remove the lever at the bottom of the appliance by loosening the 2 screws and removing them.
Ø
Remove the 4 screws at the bottom of the appliance.
Ø
Place the tray with mounted pipe opening against the bottom of the appliance.
Ø
Re-use the 4 screws to mount the tray.
Ø
Place back the lever and fasten it by means of the 2 screws.
Ø
Connect the flexible hose (Ø 80 mm) to the round pipe opening of the outside air connection.
In case of a fully closed system, always ensure an air-tight connection of the flexible hose to the round pipe
!Caution
opening by using a heat resistant sealant.
For disassembling the outside air connection, please observe the above-mentioned steps in reverse order.
Outside air connection pre-mounted (see appendix 2, fig. 22):
Ø
Connect the flexible hose (Ø 80 mm) to the round pipe opening of the outside air connection.
In case of a fully closed system, always ensure an air-tight connection of the flexible hose to the round pipe
!Caution
opening by using a heat resistant sealant.
For disassembling the outside air connection, please observe the above-mentioned steps in reverse order.
9.7.2.3 Interior lining
9.7.2.3.1 Vermiculite
The fire's vermiculite plates are located on the bottom against the side walls of the appliance. In the following
situations the vermiculite plates must be taken out:
The bottom plates are first removed and the side plates last. The insertion of the vermiculite plates takes place in
reverse order.
Make sure that the vermiculite plates are replaced in the original position!
!Caution
9.7.2.3.2 Flame baffle plates
On delivery the flame baffle plates (see appendix 2, fig. 23) are located in the top section of the appliance. The
flame baffle plates must be removed in a number of situations:
For removing the flame baffle plate, proceed as follows:
Follow the instructions below. Then repeat these instructions on the other side of the appliance.
!Caution
Ø
Lift the left side of the flame baffle plate until it gets above the edge and slide the flame baffle plate to the right.
Ø
Lower the left side of the flame baffle plate and slide the flame baffle plate to the left.
Ø
Slide the right-hand side of the flame baffle plate over the edge.
Ø
Slide the flame baffle plate to the left and lower it until it reaches the lower section of the appliance.
Ø
Now you can remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads on top (see appendix 2, fig. 23).
!Caution
42
When disassembling the air slide valve (see section 9.7.2.1).
To be able to reach the adjustable legs (see section 9.6).
When replacing the vermiculite plates.
when mounting and checking the flue gas exhaust connection;
when performing maintenance at the flue duct;
when replacing the flame baffle plates.
I N S T A L LA T I ON M A N U A L

Werbung

loading

Diese Anleitung auch für:

Instyle tunnelProstyle 700Prostyle tunnel