Herunterladen Diese Seite drucken

Dik Geurts Instyle 700 Installationsvorschrift Seite 41

Vorschau ausblenden Andere Handbücher für Instyle 700:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

IN S TA LLA TION M A N U A L
Proceed as follows when disassembling the air slide valve (see Appendix 2, Fig. 18):
Ø
Remove the vermiculite plates and the felt from the bottom (see section 9.7.1.3.1).
Ø
Remove the 5 cover plate socket screws from the bottom.
Ø
Remove the cover plate.
Ø
If there is an outside air connection remove the 2 screws from the front strip.
You only have to remove the front strip if an exterior connection is assembled.
!Caution
Ø
Remove the socket screw with spring.
Ø
Remove the air slide valve by bringing it towards you.
Ø
Check the air slide valve and clean it if necessary.
To replace the air slide valve proceed as described for removal in reverse order.
9.7.1.3 Interior lining
9.7.1.3.1 Vermiculite
The fire's vermiculite plates are located on the bottom against the rear wall and/or side walls of the appliance. In
the following situations the vermiculite plates must be taken out:
When disassembling the air slide valve (see section 9.7.1.2).
To be able to reach the adjustable legs (see section 9.6).
When replacing the vermiculite plates.
The bottom plates and the underlying felt are first removed and the rear plates last. The insertion of the
vermiculite plates takes place in reverse order.
Make sure that the vermiculite plates are replaced in the original position! The back plate with the small, not
!Caution
countersunk, holes must be placed to the front.
9.7.1.3.2 Flame baffle plate
On delivery the flame baffle plate (see appendix 2, fig. 19) is located in the top section of the appliance. The flame
baffle plate must be removed in a number of situations:
when mounting and checking the flue gas exhaust connection;
when performing maintenance at the flue duct;
when replacing the flame baffle plate.
For removing the flame baffle plate, proceed as follows:
Ø
Lift the left side of the flame baffle plate until it gets above the edge and slide the flame baffle plate to the right.
Ø
Lower the left side of the flame baffle plate and slide the flame baffle plate to the left.
Ø
Slide the right-hand side of the flame baffle plate over the edge.
Ø
Slide the flame baffle plate to the left and lower it until it reaches the lower section of the appliance.
Ø
Now you can remove the flame baffle plate.
Placing the flame baffle plate takes place in reverse order.
The stainless steel profile must be placed at the front with the screw heads on top (see appendix 2, fig. 19).
!Caution
9.7.2 Instyle Tunnel / Prostyle Tunnel
9.7.2.1 Air slide valve
Pior to installing the appliance, check the operation of the air slide (see appendix 2, fig. 20a and 20b). It is possible
that steel grit ended up in the air slide during transportation. If the air slide does not run smoothly, it has to be
cleaned. For this, the air slide should be disassembled. The suspended air slide valve is spring-mounted using a
bolt and a spring, which are located below the cover plate.
When disassembling the air slide, proceed as follows (see appendix 2, fig. 20a and 20 b):
Has an outside air connection been mounted? If so, this should be removed first (see appendix 2, fig. 20b and
!Caution
section 9.7.2.2).
Ø
Remove the vermiculite plates from the bottom (see chapter 9.7.3.2.1).
Ø
Unscrew the 5 Allen screws of the cover plate from the bottom and remove them.
Ø
Unscrew the Allen screw with spring.
Ø
Remove the air slide by bringing it towards you.
Ø
Check the air slide and clean it if necessary.
For placing back the air slide, the actions described for disassembling should be performed in reverse order.
41

Werbung

loading

Diese Anleitung auch für:

Instyle tunnelProstyle 700Prostyle tunnel