9.5 Frames
The appliances can be fitted with various frames. The frames are adjustable in depth and can be fitted so they are
parallel to the door.
The installation depth of the appliance depends on the selected frame (see Annex 2, fig. 1)!
!Caution
When assembling the frame proceed as follows:
First remove the door before assembling the frame.
Tip!
In-built frame (no frame):
Ø
Remove the 4 pre-assembled bolts/nuts (see Appendix 2, Fig. 11).
Ø
Slide the frame over the stove into the desired position (see Appendix 2, Fig. 12).
Ø
Fasten the 4 bolts and nuts (the bolts on the inside, the nuts on the outside of the appliance)
(see Appendix 2, Fig. 13).
Ø
Fasten the 2 bolts and nuts on top of the appliance (see Appendix 2, Fig. 13).
Other frames:
Ø
Loosen the 4 pre-assembled bolts (see Appendix 2, Fig. 14).
Ø
Slide the frame in the convection casing between the loosened bolts and the bolts still tight in the appliance
(see Appendix 2, Fig. 15).
Ø
Tighten the nuts. The frame is now clamped between the nuts (see Appendix 2, Fig. 16).
9.6 Adjustable feet
In order to promote a stable set-up, these appliances are provided with adjustable feet (see Annex 2,
fig. 3). These feet can be adjusted by means of the supplied socket screwdriver.
Ø
Remove the vermiculite from the bottom (see paragraph 9.7.1.3.1 (Instyle en Prostyle 700) or 9.7.2.3.1 (Instyle en
Prostyle Tunnel).
Ø
Turn the socket screwdriver to the right in order to adjust the fire upwards, and to the left to adjust the fire
downwards.
9.7 Supplementary installation instructions per appliance
9.7.1 Instyle 700 / Prostyle 700
9.7.1.1 Outside air connection
It is possible to provide the fire with an outside air connection. This outside air connection is optionally available
as an (external air) kit. This kit can be used for a connection either on the bottom or rear of the appliance and is
available through your supplier. First determine if you want a connection on the bottom or rear side.
Proceed as follows with a connection on the bottom (see Appendix 2, Fig. 17a + 17b):
Ø
Fasten the 'pipe opening' with 4 screws to the small housing.
Ø
Remove the 4 screws on the bottom side of the appliance.
Ø
Then bring the small housing with assembled 'pipe opening' against the plate on the bottom of the appliance.
Ø
Re-use the 4 screws to assemble the small housing.
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe opening' of the outside air connection.
Ø
Dispose of unused parts in the appropriate way.
Proceed as follows with a connection on the rear (see Appendix 2, Fig. 17c + 17d):
Ø
Use a hammer to break the rectangular plate out of the rear of the appliance.
Ø
Also break out the side baffle in the middle of the external air kit.
Ø
Fasten the 'pipe opening' with 4 screws to the small housing.
Ø
Assemble the large housing on the small housing using 2 screws and set this to the correct length for the relative
appliance.
Ø
Remove the 6 screws on the bottom side of the appliance.
Ø
Then bring the outside air connection against the plate on the bottom of the appliance.
Ø
Re-use the 6 screws to assemble the external air kit.
Ø
Connect the flexible hose (Ø 80 mm) to the round 'pipe opening' of the outside air connection.
9.7.1.2 Air slide valve
With installation and maintenance of the appliance check the operation of the air slide valve (see Appendix 2,
Fig. 18). There is the possibility that steel grit entered the air slide valve during transport. If the air slide valve does
not move smoothly it must be cleaned. The air slide valve must be disassembled to do this. The air slide valve is
suspended sprung by means of a bolt and a spring located below the cover plate.
40
I N S T A L LA T I ON M A N U A L

Werbung

loading

Diese Anleitung auch für:

Instyle tunnelProstyle 700Prostyle tunnel