Herunterladen Diese Seite drucken

HOLZMANN-MASCHINEN SB13B16VN 230V Betriebsanleitung Seite 33

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

14.3
Electrical connection
Dangerous electrical voltage!
Risk of injury due to dangerous electrical voltage!
 The machine may only be connected to the mains supply and the associated
checks carried out by a qualified electrician or under the instruction and super-
vision of a qualified electrician!
Check, whether the neutral connection (if existing) and the protective grounding function
properly.
Check, whether the supply voltage and the frequency correspond to the specifications of the
machine.
Deviation of the supply voltage and frequency!
A deviation from the value of the supply voltage of ±5 % is permissible. A short-circuit
fuse must be provided in the power supply system of the machine!
Use a supply cable that fulfils the electrical requirements (e.g. H07RN, H05RN) and take the
required cross-section of the supply cable from a current carrying capacity table. Pay atten-
tion to the measures for protection against mechanical damage.
Make sure that the power supply is protected by a residual current circuit breaker.
Connect the machine only to a properly grounded outlet.
When using an extension cable, make sure that the dimension matches the connected load
of the machine. The connection power can be found in the technical data, the correlation of
cable cross-section and cable lengths can be found in the technical literature or obtain infor-
mation from a specialist electrician.
A damaged cable must be replaced immediately.
HOLZMANN MASCHINEN GmbH
Attach the quick release chuck to the spindle.
Lower the spindle with the spindle travel handle until
the quick release chuck hits the wood on the drilling
table.
Apply pressure to the quick release chuck with the
spindle travel handle so that the quick release chuck
is fixed in the spindle.
6. Adjust the height of the spindle protection cover
Adjust the height of the spindle protection cover. To
do this, loosen the screw (1).
NOTE:
too low (a).
The chuck should be well concealed by the spindle protec-
tion cover (b).
After adjustment, retighten the screw (1).
WAR N I N G
N O TE
www.holzmann-maschinen.at
Take care that the spindle protection cover is not set
ASSEMBLY
33
SB13B16VN_230V

Werbung

loading