Herunterladen Diese Seite drucken

HEYLO DE2XL Betriebsanleitung Seite 34

Elektroheizer
Vorschau ausblenden Andere Handbücher für DE2XL:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electric heater DE2XL
e) After completing the task, remove all the tools
and objects from the working area around the
device.
Safety instructions regarding faults
DANGER
Electric shock arising from high voltage
when working on the electrical compo-
nents
Electric shock can cause serious injury or death.
a) Any work on the electrical system must be
performed by qualified electricians only.
b) Disconnect the device from the power supply
before performing any work on the electrical
system.
c) After completion of the work, install all pro-
tective equipment as provided at the factory.
19.1
Malfunctions during operation
NOTICE
If the device is supplied with electricity via the
power cable, work on the electrical system may
only be carried out by qualified electricians.
Only have repair work carried out by the HEYLO
Service division or by service partners of HEYLO.
Rectifying Possible cause
Device
No electricity
does not
because:
start
– Rotary selec-
Oper-
tor for
ating mode
switched off
– Residual cur-
rent device of
the indoor in-
32 / 36
Remedy
Check the power
cable and the
mains connection.
Check supply with
voltage tester.
Rectifying Possible cause
stallation
tripped
– Mains plug
disconnected
– Supply line
defective
Residual current
device of the
indoor installation
has tripped.
Safety tempera-
ture limiter trig-
gered: Intake or
blow-out temper-
ature too high, air
cannot circulate
freely,
Heating element
defective.
The device
Rotary selector
Operating
does not
for
mode
heat up
not set to
Heat
Thermostat has
tripped
Remedy
Clean the heating
element (if neces-
sary with com-
pressed air), oth-
erwise send the
device for repair.
If the device has
come into contact
with moisture,
allow it to dry out
completely prior to
operation.
device has over-
heated. Disconnect
the plug and wait
for 10 minutes to
cool down. Insert
the tool into the
reset hole on the
bottom and press
the reset button.
Turn on again.
Send the device in
for repair.
Operat-
Move the
ing mode
rotary
Heat
selector to
(1000 W or 2000
W)
Turn the
Heating
temperature
rotary
knob and listen out
EN