Connect the filter to the pump and pool
suction and return according to the diagram
opposite.
Push the tubes onto the barbed unions until
the reach the boss (bump) marking the stop
point.
The drain union is transparent, thus the
section that remains visible will act as a sight
glass to assess water turbidity.
To
facilitate
fitting
corrugated hose, you may steep the ends of
the hose in hot water to soften them.
Use the hose clips provided to make the
unions leaktight. Tighten using a wrench
rather than a screw driver.
When assembling pump unions, make sure
that the o-rings are correctly positioned in
their grooves.
5.
MULTIPORT VALVE FUNCTIONS
FILTRATION: Usual valve
position. Water from the pump
crosses the fitler from top to
bottom and returns to the pool.
CLOSED: No water circulation
is possible. The pump should
never be allowed to run when
the valve is in this position.
CIRCULATION: Water from
the pump returns directly to the
pool without passing through
the filter..
ALWAYS•STOP THE PUMP BEFORE CHANGING THE VALVE POSITION. FAILURE TO COMPLY WITH THIS INSTRUCTION
COULD ENTAIL SERIOUS DAMAGE TO THE FILTER AND CANCELLATION OF ITS GUARANTEE.
18/40
2019/05 - Indice de révision : H - Code : 26660
of
the
non-kinking
THE VALVE HANDLE POSITION IS CHANGED SIMPLY BY ROTATING IT;
DO NOT PRESS DOWN
Waste
Filtered water outlet
CAUTION:
DRAIN: Water from the pump
passes directly to waste without
passing through the filter.
BACKWASH: Water from the
pump crosses the filter from the
bottom to the top and is then
routed to waste taking with it dirt
and debris trapped by the filter.
RINSE: Water from the pump
crosses the filter from top to
bottom and is routed to waste.
CAUTION!
Pump/filter connection
Non filtered
water inlet
FILTRATION BWT myPOOL