TROUBLESHOOTING
Incorrect operations are often mistaken for trouble and malfunctions. If you think that is something wrong with this component, check the
points below. Sometimes the trouble may lie in another component. Investigate the other components and electrical appliances being used.
If the trouble cannot be rectified even after exercising the checks listed below, ask your nearest PIONEER authorized service center or your
dealer to carry out repair work.
Symptom
No power supplied to unit.
No sound.
No sound from one speaker.
Cannot record tapes.
Cannot perform tape copying.
20
<ARE1284>
En
Power plug is disconnected from outlet.
The component power plug has been plugged
into another component power outlet (e.g.
timer, etc.) but power to that unit is discon-
nected.
Connecting cords are disconnected from termi-
nals, or connected incorrectly.
Terminals, or connecting cords pin plugs are
dirty.
:
The TAPE 2/ADPT monitor switch @ is set to
ON (except when using an adaptor compo-
nent).
The cassette deck for playback connected to
TAPE 2/ADPT and the DIRECT switch © is set
to ON. (A-202 only)
Operation of other components is incorrect.
Both SPEAKERS selector switches are set to
"OFF" (A-202 only)
The position of the INPUT SELECTOR @ does
not match the component to be played back.
Connecting cords or speaker cords are discon-
nected on that side.
BALANCE
control is set to one side.
Connections are incorrect.
Operation of cassette deck is incorrect.
The TAPE 2/ADPT monitor switch @ is set to
ON.
The positions of the INPUT SELECTOR switch
@ and TAPE 2/ADPT monitor switch @ are in-
correct (when using 2 cassette decks).
Operation of cassette decks is incorrect.
Insert plug securely into outlet.
Turn on power to other component.
Connect securely.
Clean terminals and plugs.
Set switch @ to OFF.
Set the DIRECT switch © to OFF.
Consult the operating instructions for the
other components.
Set one switch or both switches to "ON".
Set the switch @ correctly (CD, PHONO,
TUNER, TAPE
1/DAT).
Connect securely.
Set BALANCE
control to center position.
Reconnect properly.
Consult the operating instructions for the cas-
sette deck.
Set the TAPE 2/ADPT monitor switch @ to
OFF.
Set switches correctly
(See section COPYING TAPES).
Consult the operating instructions for the cas-
sette decks.