Operating
controls
(I) Input jacks for the effects channel
(2) Input jacks for the regular channel
(3) Volurne control : regular channel
(4) Bass control : regular channel
(5) Bass boost switch : regular channel
(6) Mid-range
control : regular channel
(7) Mid-range
boost switch : regular channel
(8) Treble boost switch: regular channel
(9) Treble control : regular channel
(10) Volume control:
effects channel
(I I) Bass control
: effects
(12) Bass boost switch : effects channel
(13) Mid-range
control : effects channel
(14) Mid-range boost switch:
(15) Treble control : effects channel
(16) Treble boost switch : effects channel
(17) Control
reverb
(18) Vibrato intensity
(19) Vibrato frequency
(20) Mains pilot lamp
(21) Mains switch
(22) Mains fuse
(23) Fuse for transistors
(24) Fuse for transistors
(25) Coupling jack for reverb unit
(26) Mains supply socket
(27) Mains voltage selector
(28) Connection jack for vibrato/reverb
(29) Connection cable from spring reverb system
10
channel
effects channel
remote control
Operating
A)
Connection
to mains supply
Before putting the unit into operation,
the rear of the unit is set for the proper
nection to AC mains only. Setting to another
of a screw driver or a suitable
coin whidl
to the respective mains voltage. The unit is set for 220 volts in the factory. The
mains fuse (22) may be replaced
by turning
properly sized and rated fuses indicates
Underfusing
may cause blowing of the fuses even though the unit is not defective.
Mended fuses or overfusing
may cause severe damage to the unit which is not
covered
by warranty. The electrical
value is impressed
two fuse caps.
B) Fuses
The size of the mains fuse (22) is:
110—130 V =
1.6 amps.
220—240 V =
0.8 amps.
Fuses for transistors
(23), (24) = 3.15 amps. slow
Dimension
of all fuses
=
5 x 20 mm
ATTENTION!
In case that one of the fuses for transistors
still operates
but with reduced
output
bag at the left wall
inside
the cabinet.
C) Putting into operation
The earthing-contact-type
line
cord
plugged
into the mains supply sooqet (26). The specified
tric
hazard as well as the best possible
secured
when plugging
this cord line into a properly
type
sodcet.
Depending
on local
mains conditions,
polarity
of the
power
plug
in order
to secure
(unplug, tum, and plug in again).
D) Input Connectors
Four telephone-type
Jaecs (I), (2) located
the connection
of all commonly
used lead and bass guitars as well as the con-
nection
of all pick-ups
of accordions,
instructions
whether the voltage selector
(27) at
line voltage. The unit is suitable for con-
voltage is accomplished
by means
should be turned until the mark points
out the cap. Repeated
blowing
a• defect in the unit.
at the side on one of the
slow
slow
(23), (24) blows, the unit
power only. Spare fuses are in a plastic
supplied
with
the "PERFECT"
should
be
protection
against elec-
freedom
from humming
is only
installed
earthing-contact-
it may become
necessary
to change the
maximum
freedom
from
humming
at the left of the control
panel permit
and
like
instruments.
The
input
are
11
of

Werbung

loading