19 Specifications
19 Specifications
19.1 STIHL FSE 52 Trimmer
– Supply voltage: 220-240 V
– Frequency: 50/60 Hz
– Rated current: 2.3 A
– Fuse: 10 A
– Power consumption: 500 W
– Rated speed under load: 6000 rpm
– Weight with deflector ad cutting attachment
– Version with 0.3 m cable: 2.2 kg
– Version with 9.9 m cable: 2.8 kg
– Electrical protection class: II
19.2 Extension Cords
If an extension cord is used, the cross sectional area of its
conductors must meet the following minimum requirements
– depending on the line voltage and length of the extension
cord:
220 V to 240 V
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 / 2.5 mm²
100 V to 127 V
– Cord length up to 10 m: AWG 14 / 2.0 mm²
– Cord length 10 m up to 30 m: AWG 12 / 3.5 mm²
19.3 Noise and Vibration Data
K-value (uncertainty) for sound pressure levels is 2 dB(A).
K-value (uncertainty) for sound power levels is 2 dB(A). K-
value (uncertainty) for vibration levels is 2 m/s².
STIHL recommends that you wear hearing protection.
0458-777-9921-B
All manuals and user guides at all-guides.com
– Sound pressure level L
– Sound power level L
– Vibration level a
The vibration values quoted above have been measured
according to a standardized test procedure and may be used
to compare electric power tools. Depending on the type of
usage, the vibrations that actually occur may differ from the
values quoted. The vibration values quoted may be used for
an initial assessment of the user's exposure to vibrations.
The actual exposure to vibrations has to be estimated. This
process may also take into account times during which the
electric power tool is switched off and times during which it
is switched on but running off load.
For information on compliance with Vibration Directive
2002/44/EC visit www.stihl.com/vib.
19.4 REACH
REACH is an EC regulation and stands for the Registration,
Evaluation, Authorisation and Restriction of Chemical
substances.
For information on compliance with the REACH regulation
see www.stihl.com/reach.
measured according to
pA
EN 50636-2-91: 83 dB(A)
measured according to EN 50636-
wA
2-91: 94 dB(A)
measured according to EN 50636291
hv
– Control handle: < 4.5 m/s²
– Loop handle: 3.0 m/s²
English