A300
STANDSTILL MONITOR
5. 4. Start-up delay
The start-up delay suppresses an error signal as long as the machine is in the
process of starting and has not yet reached its nominal speed.
• It is set to 15 s but can be reduced by a resistor between the terminals 1
and 2.
Resistor values: between 100 k (which corresponds to 2 s) and 3.9 M (which
corresponds to 14 s).
• After application of the operating voltage the start-up delay is active only
once. If the drive is often turned on and off, couple the supply voltage of the
drive and the monitor. By doing so, the start-up delay is active every time the
drive is turned on.
Function diagram for switching functions
f
SP+Hy
SP
UB
t
ST
t
1)
ST
1) power-on delay time
ST = start-up delay
22
switch position
I and IV
switch position
II and III
1
0
1
0
1
0

Werbung