Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Ambient Conditions; Electrical Data - SSP HOLDX RL1-P8-S-B-S0129 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

2 .8 Technical data

Safety data
Performance level (EN ISO 13849-1: 2015)
category (EN ISO 13849-1: 2015)
SIL (EN IEC 62061: + A2:2015)
SIL (EN IEC 61508: 2010)
- Hardware fault tolerance
- PFH
D
Service life (EN IEC 62061)

Ambient Conditions

Operating temperature max.
Storage temperature max.
Rated impulse withstand voltage (U
imp
Pollution degree
Protection class

Electrical data

Supply voltage
Power consumption (incl. OSSD outputs)
Nominal current (at 24 VDC)
Idle current I
0
Number of safety inputs
Current consumption per input max.
Current consumption input magnet ON
Number of OSSD safety outputs
Safety output: Output type
Switching current per safety output max.
Voltage drop safety output (U
)
d
Residual current safety output (l
)
r
Load capacity safety output max.
Number of diagnosis output
Diagnosis output: Output type
Switching current per diagnosis output max.
Function diagnostic output
Further functions can be activated via HOLDX Manager software
Connection type
(Version HOLDX RL1-8P S0129 or S0131) M12 8-pin, pigtail 200 mm
Series connection for safe inputs and outputs
Protection class power supply (EN 61140: 2007-03)
Mechanical data
Electromagnet locking force
Permanent latching force
Smart latching force
Dimensions guard locking (W x H x D)
- Width
- Length
- Height
Anchor plate dimensions (W x H x D)
- Width
- Length
- Height
Process guard locking weight
Anchor plate weight
Torque (mounting screw) process guard locking
Torque (mounting screw) anchor plate
20
)
24 VDC, (+10/-15%)
1  2-channel
1  2-channel
Transistor (PNP)
100 mA (DC-12/DC-13)
Transistor (PNP)
0 = Door closed
0 = Guard locking active
1 = Door closed + Guard locking active
max. 30 process guards
Stabilized PELV/SELV power supply required
0 / 30 N / 50 N
239.6 mm without cable
Fastening
screwed connection with pan-head screws M6 Torx with pin (countersunk)
strength class min. A2/70 (yield strength > 450 N/mm² and tensile strength > 700 N/mm²)
PL e
Guard locking housing materials
Cat. 4
Anchor plate housing materials
SIL CL3
Shock resistance
SIL3
Vibration resistance
HFT 1
2.24 × 10
-9
20 years
Switching distances acc . to DIN EN 60947-5-3:2014-12
Secured switching distance ON S
Secured switching distance AUS S
-25 ... + 55°C
Typical switching distance S
-25 ... + 70°C
Repeat accuracy R switching distances
1000 V
Hysteresis
2
IP67
General times
Standby recovery time t
Switch-on delay actuator t
7 W
Safety functions times
645 mA
Switch-off reaction time inputs  outputs t
60 mA
Switch-off reaction time anchor plate  outputs t
Test pulse length OSSD safety outputs
2.75 mA
Note
1.2 mA
The power supply unit has to comply with rules and regulations for protective
extra-low voltages (SELV, PELV). The inputs and outputs of the safety switch have
to be equipped with a protective separation of voltage higher than 60 V AC.
0.75 V
Note
0.5 mA
About the scope of UL approval: The devices have been tested according to
20 nF
the requirements of UL508 and CSA/ C22.2 no. 14 (Protection against electric
shock and fire).
1
100 mA
III
1200 N
50 N
34.4 mm
31.1 mm
34.4 mm
224.1 mm
20.1 mm
725 g
475 g
6 Nm
6 Nm
HOLDX RL1-P8-S-B-S0129
HOLDX RL1-P8-W-B-S0131
Fixation with a medium-strength threadlocker, e.g. Loctite 243
PBT GF30, aluminum anodized black, AlMgSi, TPE, PC
PBT GF30, aluminum anodized black, S235 nickel-plated, EPDM/CR
10-150 Hz, Amplitude 1 mm, 5 g
ao
ar
n
v
on
off
off
30 g / 11 ms
10-500 Hz, 3 g RMS
6 mm
18 mm
11 mm
< 0.5 mm
2 mm
1000 ms
75 ms
max. 3 ms
max. 75 ms
0.3 ms
EN

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Holdx rl1-p8-w-b-s0131

Inhaltsverzeichnis