Notes to the user
1.1
Validity
This guide describes the construction, function and setup
options for the BTL7 Micropulse Transducer with digital
(P) interface. It applies to types
BTL7-P511 -M _ _ _ _ -P-S32/S115/KA_ _
(see Type code breakdown from page 22).
The guide is intended for qualified technical personnel. Read
this guide before installing and operating the transducer.
1.2
Symbols and conventions
Individual instructions are indicated by a preceding
triangle.
► Instruction 1
Action sequences are numbered consecutively:
1. Instruction 1
2. Instruction 2
Note, tip
This symbol indicates general notes.
1.3
Scope of delivery
BTL7 transducer
Mounting clamps with insulating sleeves and screws
Condensed guide
The magnets are available in various models
and must be ordered separately.
1.4
Approvals and markings
UL approval
File no.
E227256
US Patent 5 923 164
The US patent was awarded in connection with this
product.
www.balluff.com
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
The transducer meets the requirements of the following
product standards:
EN 61326-2-3 (noise immunity and emission)
Emission tests:
RF emission EN 55011
Noise immunity tests:
Static electricity (ESD)
EN 61000-4-2
Electromagnetic fields (RFI)
EN 61000-4-3
Electrical fast transients (burst)
EN 61000-4-4
Surge
EN 61000-4-5
Conducted interference induced by
high-frequency fields
EN 61000-4-6
Magnetic fields
EN 61000-4-8
More detailed information on the guidelines,
approvals, and standards is included in the
declaration of conformity.
Severity level 3
Severity level 3
Severity level 3
Severity level 2