Herunterladen Inhalt Inhalt Diese Seite drucken

Hilti HIT FP 700-R Bedienungsanleitung Seite 6

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

European technical assessment ETA-2 1 / 0 6 2 4
English translation prepared by CSTB
Figure A4:
Rebar connection for components stressed primarily in compression
Figure A5:
Anchoring of reinforcement to cover the enveloped line of acting tensile force in the bending
member
Note to Figure A1 to Figure A5:
In the Figures no transverse reinforcement is plotted, the transverse reinforcement as required by
EN 1992-1-1:2004+AC:2010 shall be present.
The shear transfer between existing and new concrete shall be designed according to
EN 1992-1-1:2004+AC:2010.
Preparing of joints according to Annex B2.
The reference to EN 1992-1-1:2004+AC:2010 is cited in the following as EN 1992-1-1 only.
Injection system Hilti HIT-FP 700 R for rebar connections
Product description
Installed condition and application examples of post-installed rebars
Page 5 of 22 | 1 7 / 0 6 / 2 0 2 2
Annex A2