European technical assessment ETA-2 1 / 0 6 2 4
English translation prepared by CSTB
Specific Part
1
Technical description of the product
The Hilti HIT-FP 700 R is used for the connection, by anchoring or overlap joint, of reinforcing bars
(rebars) in existing structures made of ordinary non-carbonated concrete C12/15 to C50/60.
This ETA covers anchoring systems consisting of Hilti HIT-FP 700 R bonding material and an
embedded straight deformed reinforcing bar diameter, d, from 8 to 40 mm with properties according
to Annex C of EN 1992-1-1:2004 and EN 10080:2005. The classes B and C of the rebar are
recommended. The illustration and the description of the product are given in Annexes A.
2
Specification of the intended use
The performances given in Section 3 are only valid if the anchor is used in compliance with the
specifications and conditions given in Annexes B.
The provisions made in this European technical assessment are based on an assumed working
life of the anchor of 100 years. The indications given on the working life cannot be interpreted as a
guarantee given by the producer, but are to be regarded only as a means for choosing the right
products in relation to the expected economically reasonable working life of the works.
3
Performance of the product
Mechanical resistance and stability (BWR 1)
3.1
Essential characteristic
Characteristic resistance under static and quasi-static
loading
Safety in case of fire (BWR 2)
3.2
Essential characteristic
Reaction to fire
Resistance to fire
Hygiene, health and the environment (BWR 3)
3.3
Regarding dangerous substances contained in this European technical approval, there may be
requirements applicable to the products falling within its scope (e.g. transposed European
legislation and national laws, regulations and administrative provisions).
Safety in use (BWR 4)
3.4
For Basic requirement Safety in use the same criteria are valid as for Basic Requirement
Mechanical resistance and stability.
Protection against noise (BWR 5)
3.5
Not relevant.
Page 2 of 22 | 1 7 / 0 6 / 2 0 2 2
Performance
See Annex C1 and C2
Performance
Anchorages satisfy requirements
for Class A1
See Annex C3