14. PROBLEM IDENTIFICATION
PROBLEM
1. With the key turned to 
«ON», the light stays 
off (for rear collection
models only
2. With the key turned 
to «START» the light
flashes and the starter 
motor does not run 
(for rear collection
models only)
3.  With the key turned 
to «START» the light
is on but the starter
motor does not run 
(for rear collection
models only)
If problems persist after having performed the above operations, contact your dealer.
PROBABLE CAUSE
The safety device of the electronic 
circuit board has cut in due to:
badly connected battery
battery terminals crossed
flat battery
fuse blown
wet circuit board
starting conditions have not been met
insufficiently charged battery
malfunction on the starter relay
Turn the ignition key to «STOP» position 
and look for the cause of the problem:
check the connections (par. 4.4)
check the connections (par. 4.4).
recharge the battery (par. 7.5)
replace fuse (10 A) (par. 8.5).
dry using luke warm air
check that all starting conditions are met  
(par. 6.2.2)
recharge the battery (par. 7.5)
contact your Dealer
EN - 22
REMEDY